Installation and operation manual
68
EKEQ EKEQDCBV3
Option kit for combination of Daikin condensing units
with field supplied air handling units
4P383212-1 - 2014.08
C
ONTENTS
Page
Introduction ............................................................. 68
Installation ............................................................... 69
Accessories..................................................................................... 69
Name and function of parts............................................................. 69
Before installation............................................................................ 69
Selecting the installation site........................................................... 71
Refrigerant piping work ................................................................... 71
Piping installation ............................................................................ 71
Valve kit installation ......................................................................... 72
Installation of the electrical control box ........................................... 73
Electric wiring work ......................................................................... 74
Installation of thermistors ................................................................ 77
Test operation.................................................................................. 78
Operation and maintenance................................... 78
What to do before operation............................................................ 78
Operation and display signals ......................................................... 80
Troubleshooting ............................................................................... 81
Maintenance.................................................................................... 81
Disposal requirements .................................................................... 81
The English text is the original instruction. Other languages are
translations of the original instructions.
I
NTRODUCTION
Field-supplied air handling units can be connected with a
Daikincondensing unit via a control box and expansion valve kit. Each
airhandling unit can be connected with 1 control box and 1
expansionvalve kit. This manual describes the installation of the
expansionvalve kit and the installation and operation of 2 types of
control boxes.
We distinguish 2 different control boxes, each with its own application
and installation requirements.
EKEQFCBA control box (3 possible operation modes)
Operation with 0–10 V input to control the capacity
An external controller is needed to control the capacity. For
details of the necessary functions of the external controller
refer to paragraph "Operation with 0–10 V capacity control:
X-control" on page 79. There are 2 different 0-10 V operation
modes that can be used to control the room temperature or
air discharge temperature.
Operation with fixed T
e
/T
c
temperature control
- In cooling this system operates on a fixed evaporating
temperature.
- In heating this system operates on a fixed condensing
temperature.
EKEQDCB control box
The system will operate as a standard indoor unit to control the
room temperature. This system does not require a specific
external controller.
Connectivity to DIII-net devices only allowed with:
- ITouch Manager II
- Modbus interface DIII
This equipment is not designed for year-round cooling
applications with low indoor humidity conditions, such as
Electronic Data Processing rooms.
This appliance is not intended for use by persons, including
children, with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance
by a person responsible for their safety.
Children should be supervised to ensure that they do not play
with the appliance.
EKEQFCBAV3
EKEQDCBV3
Option kit for combination of Daikin condensing units
with field supplied air handling units
Installation and
operation manual
READ THESE INSTRUCTIONS CAREFULLY BEFORE
INSTALLATION AND OPERATION.
IMPROPER INSTALLATION OR ATTACHMENT OF
EQUIPMENT OR ACCESSORIES COULD RESULT IN
ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR
OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY
TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE
SPECIFICALLY DESIGNED FOR USE WITH THE
EQUIPMENT AND HAVE THEM INSTALLED BY A
PROFESSIONAL.
IF UNSURE OF INSTALLATION PROCEDURES OR USE,
ALWAYS CONTACT YOUR DAIKIN DEALER FOR
ADVICE AND INFORMATION.
Do only use this system in combination with a field
supplied air handling unit. Do not connect this system
to other indoor units.
Only optional controls as listed in the optional
accessories list can be used.
Содержание ERQ Series
Страница 2: ......
Страница 16: ...Combination Table ESiEN09 06 A 6 General Information...
Страница 17: ...ESiEN09 06 A Specifications 7 1 Specifications 8 1 1 Outdoor Units 8...
Страница 33: ...ESiEN09 06 A Function general Function 23 1 2 Operation Mode...
Страница 58: ...Outline of Control ESiEN09 06 A 48 Function...
Страница 70: ...Wiring Diagram of Control Box ESiEN09 06 A 60 Control Box EKEQ CBV3 3 Wiring Diagram of Control Box 3 1 D box...
Страница 71: ...ESiEN09 06 A Wiring Diagram of Control Box Control Box EKEQ CBV3 61 3 2 F box...
Страница 109: ...Test Operation ESiEN09 06 A 100 Test Operation 1 2 2 Turn power on...