7
|
Unit installation
Installer reference guide
67
EWSAH/X06D
Daikin Altherma 3 WS
4P675764-1 – 2022.04
a
b
a
Water drain valve
b
Central water loop drain valve
NOTICE
Ensure that no water can enter the switch box of the hydro module.
5
Perform the remaining steps as described in
7.2.4 To close the indoor unit
1
If applicable, reinstall the left side panel.
2
If applicable, reinsert the hydro module.
3
If applicable, close the cover of the main switch box and reinstall the front
panel.
4
Close the cover of the installer switch box.
5
Reconnect the cables to the user interface panel.
6
Reinstall the user interface panel.
7
Reinstall the top panel.
NOTICE
When closing the indoor unit cover, make sure that the tightening torque does NOT
exceed 4.1 N•m.
7.3 Mounting the indoor unit
7.3.1 About mounting the indoor unit
When
Mount the indoor unit before you connect the central water loop piping and the
water piping.