7
|
Unit installation
Installer reference guide
59
EWSAH/X06D
Daikin Altherma 3 WS
4P675764-1 – 2022.04
7 Unit installation
In this chapter
7.1 Preparing the installation site
Choose an installation location with sufficient space to transport the unit in and
out of the site.
Do NOT install the unit in places often used as work place. In case of construction
works (e.g. grinding works) where a lot of dust is created, the unit MUST be
covered.
WARNING
The appliance shall be stored in a room without continuously operating ignition
sources (example: open flames, an operating gas appliance or an operating electric
heater).
7.1.1 Installation site requirements of the indoor unit
INFORMATION
Also read the precautions and requirements in the
▪
Mind the following spacing installation guidelines:
≥300
≥600
≥500
(mm)
INFORMATION
If you have limited installation space and need to install the option kit EKGSPOWCAB
(= power cable for split power supply), remove the left side panel before installing
the unit in its final position. See
"7.2.2 To open the indoor unit"
61].
▪
The indoor unit is designed for indoor installation only and for ambient
temperatures ranging from 5~35°C.