9/11
Breadcrumb Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
9.I
[6-08]
R/W
2~20°C, step: 1°C
10°C
9.I
[6-09]
0
9.I
[6-0A]
R/W
30~[6-0E]°C, step: 1°C
60°C
9.I
[6-0B]
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
9.I
[6-0C]
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
9.I
[6-0D]
R/W
0: Reheat only
1: sched.
2: Scheduled only
9.I
[6-0E]
R/W
40~60°C, step: 1°C
60°C
9.I
[7-00]
0
9.I
[7-01]
2
9.I
[7-02]
R/W
0: 1 LWT zone
1: 2 LWT zones
9.I
[7-03]
2.5
9.I
[7-04]
0
9.I
[7-05]
R/W
0: Very high
1: High
2: Medium
3: Low
4: Very low
9.I
[7-06]
R/W
0: Disabled
1: Enabled
9.I
[7-07]
R/W
0: Disabled
1: Enabled
9.I
[8-00]
R/W
0~20 min, step 1 min
1 min
9.I
[8-01]
R/W
5~95 min, step: 5 min
30 min
9.I
[8-02]
R/W
0~10 hour, step: 0,5 hour
0,5 hour
9.I
[8-03]
50
9.I
[8-04]
R/W
0~95 min, step: 5 min
95 min
9.I
[8-05]
R/W
0: No
1: Yes
9.I
[8-06]
R/W
0~10°C, step: 1°C
5°C
9.I
[8-07]
R/W
[9-03]~[9-02], step: 1°C
18°C
9.I
[8-08]
R/W
[9-03]~[9-02], step: 1°C
20°C
9.I
[8-09]
R/W
[9-01]~[9-00], step: 1°C
35°C
9.I
[8-0A]
R/W
[9-01]~[9-00], step: 1°C
33°C
9.I
[8-0B]
13
9.I
[8-0C]
10
9.I
[8-0D]
16
9.I
[9-00]
R/W
[2-0C]=0
37~55, step: 1°C
55°C
[2-0C]
≠
0
37~65, step: 1°C
65°C
9.I
[9-01]
R/W
15~37°C, step: 1°C
15°C
9.I
[9-02]
R/W
18~22°C, step: 1°C
22°C
9.I
[9-03]
R/W
5~18°C, step: 1°C
5°C
9.I
[9-04]
R/W
1~4°C, step: 1°C
4°C
9.I
[9-05]
R/W
15~37°C, step: 1°C
15°C
9.I
[9-06]
R/W
[2-0C]=0
37~55, step: 1°C
55°C
[2-0C]
≠
0
37~65, step: 1°C
65°C
9.I
[9-07]
R/W
5~18°C, step: 1°C
5°C
9.I
[9-08]
R/W
18~22°C, step: 1°C
22°C
9.I
[9-0C]
R/W
1~6°C, step: 0,5°C
1 °C
9.I
[9-0D]
R/W
0~8, step:1
0: No limitation
1~4: 90~60% pump speed
5~8: 90~60% pump speed during
sampling
6
9.I
[9-0E]
6
9.I
[A-00]
1
9.I
[A-01]
0
9.I
[A-02]
0
9.I
[A-03]
0
9.I
[A-04]
R/W
0: 2°C
1: -2°C
2: -4°C
3: -6°C
4: -9°C
5: -12°C
6: -15°C
7: -18°C
9.I
[B-00]
0
9.I
[B-01]
0
9.I
[B-02]
0
What is the waterloop anti freeze temperature?
--
--
--
--
Minimum running time for domestic hot water operation.
What is the hysteresis to be used in reheat mode?
--
--
--
Compressor forced off
--
How many leaving water temperature zones are there?
Boiler efficiency
--
--
What is the maximum desired LWT for main zone in heating?
Additional running time for the maximum running time.
Allow modulation of the LWT to control the room temp?
Leaving water temperature maximum modulation.
What is the desired comfort main LWT in cooling?
What is the desired eco main LWT in cooling?
What is the desired comfort main LWT in heating?
What is the desired eco main LWT in heating?
What is the mimimum desired LWT for main zone in heating?
What is the maximum desired LWT for main zone in cooling?
What is the mimimum desired LWT for main zone in cooling?
Leaving water temperature overshoot temperature.
What is the mimimum desired LWT for add. zone in heating?
What is the maximum desired LWT for add. zone in heating?
What is the mimimum desired LWT for add. zone in cooling?
What is the maximum desired LWT for add. zone in cooling?
Room temperature hysteresis.
Pump speed limitation
--
--
--
--
--
BBR16 limit activated?
--
Maximum running time for domestic hot water operation.
Anti-recycling time.
What is the desired reheat temperature?
What is the desired DHW production type?
What is the maximum temperature setpoint?
What is the desired comfort storage temperature?
What is the desired eco storage temperature?
--
(*1) *X*_(*2) *H*
4P675763-1 - 2021.10