Locate the 3 ¼” X 10 duct mounting flange included 

2. 

with the unit. Attach it to the open exhaust hole using 

the two (2) screws removed in step 1, with the flange 

facing outward.

Locate the vent cover included with the unit. Also locate 

3. 

the supplied foam tape. Peel the backing off the tape 

and attach it to the right and left flanges on the inside 

of the vent cover.
Remove and retain the three (3) wing nuts from the top 

4. 

retainer bracket on the front of the unit. Remove the 

bracket.
Slide the bottom flange of the vent cover into the bot-

5. 

tom retainer bracket with the wiring diagram facing out.
Cover the opening on the front of the unit by pushing 

6. 

the vent cover against it.
Make sure that the foam tape on the cover creates a 

7. 

good seal on the right and left sides of the opening. 

IMPORTANT:

 To prevent interference with the internal 

moving parts, make sure the cover is properly centered 

over the opening.
Reinstall the top retainer bracket over the top of the 

8. 

vent cover flange. Secure it in place with the three (3) 

wing nuts removed in step 4.

Parts List

Product literature

• 

Vent cover

• 

Anchoring legs

• 

2 wood screws, #14 x 2 1/2 (PN 83047)

• 

3 wire nuts

• 

2 sheet metal screws, #10 x 1/2 (PN 83022)

• 

3 ¼” X 10 duct mounting flange

• 

2 keps nuts, 1/4-20 (PN 83049)

• 

2 flat washers, 1/4-20 (PN 83203)

• 

Insulation foam

• 

Installation Preparation

 wARNING

If the electrical service does not meet the 

• 

Electrical 

Specifications

 on page 4, do not proceed with the 

installation. Call a licensed electrician to install an 

electrical circuit that meets the specifications.
Install the vent only in a vertical orientation. Do not 

• 

mount the vent on a slant or angle.
Do not enlarge or modify the exhaust knock outs or 

• 

cut an exhaust hole in a location on the chassis other 

than those shown. Doing so may cause an increase 

in noise and decrease performance.

Loosely attach the anchoring legs to the studs on the 

• 

left and right sides of the raised vent using the provided 

keps nuts and washers.

Installation Preparation for Raised Vent with 

ILHSF or REMP Series Blower:

NOTE: 

For units using the CABP3 cabinet blower, skip to 

Installing the Vent in the Cutout

 on the next page.

Remove and retain the two (2) screws on the cover 

1. 

plate over the exhaust that will be used (bottom or 

side). Discard the cover plate that was removed, but 

leave the two other cover plates in place.

Installation Instructions

Bottom 

cover

Exhaust Cover Removal (bottom shown)

Exhaust flange

Exhaust Flange Installation (bottom shown)

Adjustable

anchor legs

Front of 

raised vent

Top retainer 

bracket

Bottom retainer 

bracket

Vent cover

Flange

Attach 

foam to 

right/left 

flanges

Vent Cover Installation

Содержание RV30

Страница 1: ...ludes installation instructions for optional cabinet blower Dacor model CABP3 Part No 85515 Rev H Use these downdraft raised vents only with approved Dacor cooktops See the installation instructions f...

Страница 2: ...ller In the interest of safety and to minimize problems read these installation instructions completely and care fully before you begin the installation process Leave these installation instructions w...

Страница 3: ...ican Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not c damage electrical wiring and other hi...

Страница 4: ...e connect only one of the specified blowers Warning General Safety Precautions To reduce the risk of fire electric shock serious injury or death when using your appliance follow basic safety precau ti...

Страница 5: ...16 14 mm 3 1 8 79 mm 2 51 mm B A Adjustable anchor legs 1 13 16 46 mm 1 15 16 49 mm 3 16 5 mm Top cap with vent down 7 178 mm 7 1 2 191 mm Front View 15 16 24 mm 28 711 mm to 34 864 mm Tolerances 1 16...

Страница 6: ...atest revision and local codes and ordinances A copy of this standard may be obtained from National Fire Protection Association 1 Batterymarch Park Quincy Massachusetts 02269 9101 Electrical Supply Re...

Страница 7: ...s cooktops a 90 degree elbow must be connected to the cooktop gas inlet see dia gram at right to avoid interference with the raised vent s front panel Installation Specifications Example of Gas Line R...

Страница 8: ...all Exhaust ILHSF series in line blower 3 1 4 X 10 to round transition Duct work Duct work Outside wall Cooktop Wall cap on outside wall Raised vent Raised vent configured for bottom exhaust Floor Wir...

Страница 9: ...0 CFM ILHSF8 600 CFM ILHSF10 1100 CFM REMP3 600 CFM REMP16 1000 CFM Nominal rating at zero inches static pressure see the CABP3 Cabinet Blower Data on page 15 for actual rating Nominal rating at zero...

Страница 10: ...Bottom exhaust configutation with rear or bottom duct routing DUCT DUCT C L CABP3 Cooktop 25 5 8 651 mm Duct connection center line A Raised vent center line Countertop 3 1 4 X 10 Duct connection Duc...

Страница 11: ...l area than the required duct sizes in the table to the right For best performance keep the duct run as short as possible and never exceed the maximums stated at the right The maximum straight duct le...

Страница 12: ...flange 2 keps nuts 1 4 20 PN 83049 2 flat washers 1 4 20 PN 83203 Insulation foam Installation Preparation warning If the electrical service does not meet the Electrical Specifications on page 4 do n...

Страница 13: ...m tape supplied with the raised vent 1 Place the blower on the floor in the orientation it will be mounted on the front of the raised vent Peel the back ing off the tape and attach it to the right and...

Страница 14: ...t surfaces Make sure power to the junction box that will sup 1 ply power to the raised vent is turned off at the circuit breaker or fuse box Remove the screws from the front of the raised vent 2 elect...

Страница 15: ...CABP3 electrical panel Wire nut 3 places To blower Electrical Wiring Remote or In line Blower Installations ILHSF or REMP series REMP series blower shown Floor Raised vent electrical connections see...

Страница 16: ...lower and check for obstructions interfering with the raising mechanism Replace the vent cover or cabinet blower and make sure it is properly centered over the opening on the front of the raised vent...

Страница 17: ...iring Diagram Airflow CFM Cubic feet minute Static pressure inches of water 0 1 0 2 0 3 0 4 0 5 0 100 200 300 400 500 600 CABP3 Blower Performance POWER CONTROL CIRCUIT BOARD TO PUSH BUTTON CIRCUIT BO...

Страница 18: ...16 Notes...

Страница 19: ......