background image

Installation Instructions .................................................. 10

Parts List ........................................................................ 10

Installation Preparation .................................................. 10

Installing the Vent in the Cutout ......................................11

Electrical Installation ...................................................... 12

Final Installation ............................................................. 14

Verifying Proper Operation ............................................. 14

Installation Checklist ...................................................... 14

Technical Data ................................................................. 15

RV Raised Vent Wiring Diagram .................................... 15

CABP3 Cabinet Blower Ratings ..................................... 15

Table of Contents

Before You Begin...

Important Safety Instructions .......................................... 1

Important Information About Safety Instructions .............. 1

Safety Symbols and Labels ............................................. 1

General Safety Precautions ............................................. 2

Product Specifications ..................................................... 3

Product Dimensions ......................................................... 3

Installation Specifications ................................................ 4

Electrical Specifications ................................................... 4

Planning the Installation ................................................... 4

Planning the Duct Work ................................................... 7

All specifications subject to change without notice. Dacor

 

assumes no liability for changes to specifications.

Tested in accordance with the latest edition of ANSI Z 21.1 standard for household gas

cooking appliances, ANSI/UL 858 household electrical ranges, CAN/CSA-C22.2 NO. 64 Standard for Household 

Electric Cooking and Liquid Heating Appliances, and UL 507 electric fans.

Important:

Installer:

• 

 In the interest of safety and to minimize problems, read these installation instructions completely and care-

fully before you begin the installation process. Leave these installation instructions with the customer.

Customer:

• 

 Keep these installation instructions for future reference and the local building inspector’s use.

© 2007 Dacor, all rights reserved.

If You Need Help...

If you have questions or problems with installation, contact 

your Dacor dealer or the Dacor Customer Service Team. 

For repairs to Dacor appliances under warranty call the 

Dacor Distinctive Service line. Whenever you call, have the 

model and serial number of the appliance ready. The model 

and serial number are printed on the product data label on 

the front of the unit. The product data label also specifies 

the power supply requirements.

Dacor Customer Service

Phone: (800) 793-0093 (U.S.A. and Canada) 

Monday - Friday 6:00 

a

.

m

.

 to 5:00 

p

.

m

.

 Pacific Time

Web site: www.Dacor.com

Dacor Distinctive Service (repairs under warranty only)

Phone: (877) 337-3226 (U.S.A. and Canada) 

Monday - Friday 6:00 

a

.

m

.

 to 4:00 

p

.

m

.

 Pacific Time

Customer Service Information

Model Identification:

RV30 = 30-inch wide raised vent
RV36 = 36-inch wide raised vent
RV46 = 46-inch wide raised vent

Содержание RV30

Страница 1: ...ludes installation instructions for optional cabinet blower Dacor model CABP3 Part No 85515 Rev H Use these downdraft raised vents only with approved Dacor cooktops See the installation instructions f...

Страница 2: ...ller In the interest of safety and to minimize problems read these installation instructions completely and care fully before you begin the installation process Leave these installation instructions w...

Страница 3: ...ican Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not c damage electrical wiring and other hi...

Страница 4: ...e connect only one of the specified blowers Warning General Safety Precautions To reduce the risk of fire electric shock serious injury or death when using your appliance follow basic safety precau ti...

Страница 5: ...16 14 mm 3 1 8 79 mm 2 51 mm B A Adjustable anchor legs 1 13 16 46 mm 1 15 16 49 mm 3 16 5 mm Top cap with vent down 7 178 mm 7 1 2 191 mm Front View 15 16 24 mm 28 711 mm to 34 864 mm Tolerances 1 16...

Страница 6: ...atest revision and local codes and ordinances A copy of this standard may be obtained from National Fire Protection Association 1 Batterymarch Park Quincy Massachusetts 02269 9101 Electrical Supply Re...

Страница 7: ...s cooktops a 90 degree elbow must be connected to the cooktop gas inlet see dia gram at right to avoid interference with the raised vent s front panel Installation Specifications Example of Gas Line R...

Страница 8: ...all Exhaust ILHSF series in line blower 3 1 4 X 10 to round transition Duct work Duct work Outside wall Cooktop Wall cap on outside wall Raised vent Raised vent configured for bottom exhaust Floor Wir...

Страница 9: ...0 CFM ILHSF8 600 CFM ILHSF10 1100 CFM REMP3 600 CFM REMP16 1000 CFM Nominal rating at zero inches static pressure see the CABP3 Cabinet Blower Data on page 15 for actual rating Nominal rating at zero...

Страница 10: ...Bottom exhaust configutation with rear or bottom duct routing DUCT DUCT C L CABP3 Cooktop 25 5 8 651 mm Duct connection center line A Raised vent center line Countertop 3 1 4 X 10 Duct connection Duc...

Страница 11: ...l area than the required duct sizes in the table to the right For best performance keep the duct run as short as possible and never exceed the maximums stated at the right The maximum straight duct le...

Страница 12: ...flange 2 keps nuts 1 4 20 PN 83049 2 flat washers 1 4 20 PN 83203 Insulation foam Installation Preparation warning If the electrical service does not meet the Electrical Specifications on page 4 do n...

Страница 13: ...m tape supplied with the raised vent 1 Place the blower on the floor in the orientation it will be mounted on the front of the raised vent Peel the back ing off the tape and attach it to the right and...

Страница 14: ...t surfaces Make sure power to the junction box that will sup 1 ply power to the raised vent is turned off at the circuit breaker or fuse box Remove the screws from the front of the raised vent 2 elect...

Страница 15: ...CABP3 electrical panel Wire nut 3 places To blower Electrical Wiring Remote or In line Blower Installations ILHSF or REMP series REMP series blower shown Floor Raised vent electrical connections see...

Страница 16: ...lower and check for obstructions interfering with the raising mechanism Replace the vent cover or cabinet blower and make sure it is properly centered over the opening on the front of the raised vent...

Страница 17: ...iring Diagram Airflow CFM Cubic feet minute Static pressure inches of water 0 1 0 2 0 3 0 4 0 5 0 100 200 300 400 500 600 CABP3 Blower Performance POWER CONTROL CIRCUIT BOARD TO PUSH BUTTON CIRCUIT BO...

Страница 18: ...16 Notes...

Страница 19: ......

Страница 20: ...Dacor 600 Anton Blvd Suite 1000 Costa Mesa CA 92626 Phone 800 793 0093 Fax 626 403 3130 www Dacor com...

Отзывы: