5

The raised vent exhaust may be configured to vent 

• 

through the bottom or through one of the sides. Allow 

room for the exhaust duct coming out of the unit. 

See 

Planning the Duct Work

 (page 7) for additional 

details.
The maximum allowable duct run must be taken 

• 

into consideration when determining the layout. See 

Planning the Duct Work

 for further details.

Access from the front of the cabinet to the underside of 

• 

the cooktop, the vent system and the electrical and gas 

supplies for the cooktop and vent must be provided for 

inspection and service. Any drawers or shelves placed 

below the cooktop and in front of the vent must be easy 

to remove for access to the cooktop, vent and utilities.
For installation with gas cooktops, a 90-degree elbow 

• 

must be connected to the cooktop gas inlet (see dia-

gram at right) to avoid interference with the raised 

vent’s front panel.

Installation Specifications

Example of Gas Line Routing for Gas Cooktop 

Installations - Side View

Example of Layout with 

Cabinet Blower, Exhaust Through wall 

90

° 

elbow 

Gas line with 

regulator 

attached

Raised vent with 

cabinet blower 

mounted to front

Cabinet blower

Cabinet blower

3 1/4” X 10” 

90

° 

elbow

Wall cap

Wall

Cooktop

Raised vent

Backsplash

Duct directly through rear 

wall to wall cap

12” Min. 

(305 mm) 

Floor

Example of Layout with 

Remote Blower, Roof Exhaust

REMP16 series 

remote blower

Floor

Wall board

Cooktop

Raised vent 

configured for 

bottom exhaust

Backsplash

Duct work 

between raised 

vent and remote 

blower

Wiring/conduit that supplies power 

to remote blower (see 

Electrical 

Installation

, page 10)

3 1/4” X 10” 

to 10” round 

transition and 

45

° 

adjustable elbow

Содержание RV30

Страница 1: ...ludes installation instructions for optional cabinet blower Dacor model CABP3 Part No 85515 Rev H Use these downdraft raised vents only with approved Dacor cooktops See the installation instructions f...

Страница 2: ...ller In the interest of safety and to minimize problems read these installation instructions completely and care fully before you begin the installation process Leave these installation instructions w...

Страница 3: ...ican Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not c damage electrical wiring and other hi...

Страница 4: ...e connect only one of the specified blowers Warning General Safety Precautions To reduce the risk of fire electric shock serious injury or death when using your appliance follow basic safety precau ti...

Страница 5: ...16 14 mm 3 1 8 79 mm 2 51 mm B A Adjustable anchor legs 1 13 16 46 mm 1 15 16 49 mm 3 16 5 mm Top cap with vent down 7 178 mm 7 1 2 191 mm Front View 15 16 24 mm 28 711 mm to 34 864 mm Tolerances 1 16...

Страница 6: ...atest revision and local codes and ordinances A copy of this standard may be obtained from National Fire Protection Association 1 Batterymarch Park Quincy Massachusetts 02269 9101 Electrical Supply Re...

Страница 7: ...s cooktops a 90 degree elbow must be connected to the cooktop gas inlet see dia gram at right to avoid interference with the raised vent s front panel Installation Specifications Example of Gas Line R...

Страница 8: ...all Exhaust ILHSF series in line blower 3 1 4 X 10 to round transition Duct work Duct work Outside wall Cooktop Wall cap on outside wall Raised vent Raised vent configured for bottom exhaust Floor Wir...

Страница 9: ...0 CFM ILHSF8 600 CFM ILHSF10 1100 CFM REMP3 600 CFM REMP16 1000 CFM Nominal rating at zero inches static pressure see the CABP3 Cabinet Blower Data on page 15 for actual rating Nominal rating at zero...

Страница 10: ...Bottom exhaust configutation with rear or bottom duct routing DUCT DUCT C L CABP3 Cooktop 25 5 8 651 mm Duct connection center line A Raised vent center line Countertop 3 1 4 X 10 Duct connection Duc...

Страница 11: ...l area than the required duct sizes in the table to the right For best performance keep the duct run as short as possible and never exceed the maximums stated at the right The maximum straight duct le...

Страница 12: ...flange 2 keps nuts 1 4 20 PN 83049 2 flat washers 1 4 20 PN 83203 Insulation foam Installation Preparation warning If the electrical service does not meet the Electrical Specifications on page 4 do n...

Страница 13: ...m tape supplied with the raised vent 1 Place the blower on the floor in the orientation it will be mounted on the front of the raised vent Peel the back ing off the tape and attach it to the right and...

Страница 14: ...t surfaces Make sure power to the junction box that will sup 1 ply power to the raised vent is turned off at the circuit breaker or fuse box Remove the screws from the front of the raised vent 2 elect...

Страница 15: ...CABP3 electrical panel Wire nut 3 places To blower Electrical Wiring Remote or In line Blower Installations ILHSF or REMP series REMP series blower shown Floor Raised vent electrical connections see...

Страница 16: ...lower and check for obstructions interfering with the raising mechanism Replace the vent cover or cabinet blower and make sure it is properly centered over the opening on the front of the raised vent...

Страница 17: ...iring Diagram Airflow CFM Cubic feet minute Static pressure inches of water 0 1 0 2 0 3 0 4 0 5 0 100 200 300 400 500 600 CABP3 Blower Performance POWER CONTROL CIRCUIT BOARD TO PUSH BUTTON CIRCUIT BO...

Страница 18: ...16 Notes...

Страница 19: ......

Страница 20: ...Dacor 600 Anton Blvd Suite 1000 Costa Mesa CA 92626 Phone 800 793 0093 Fax 626 403 3130 www Dacor com...

Отзывы: