8

Installation Specifications

 

 Side Exhaust Locations (3 1/4” X 10”)

 

 

 

 

 Vertical center line of bottom exhaust lines up with vertical 

      

 

center line of chassis 

 

 

 

 Internal cabinet blower mounting location 

 Bottom Exhaust Location (3 1/4” X 10”)

 

 

CL

CL

CL

1 7/8" *

(48 mm)

1 7/8" * (48 mm)

Front View

Bottom View

14 3/8"

(365 mm)

 

 

 

*Back of unit lines   

 up with back of 

 cutout

Model

A

B

C

RV30 

RV36

2” (51 mm)

6” (152 mm)

12” (205 mm)

RV46

5” (127 mm) 9” (229 mm)

9” (229 mm)

RV

8 3/8" (213 mm)

from back of RV

cutout to center line

of CABP3 exhaust

in any orientation

(bottom, or side 

exahust)

Bottom exhaust

configutation

with rear or bottom

duct routing

DUCT

DUCT

CL

CABP3

Cooktop

25 5/8"

(651 mm)

Duct connection

center line

A

Raised vent

center line

Countertop

3 1/4 X 10

 Duct connection

Duct connection

center line

B

Raised vent

center line

Countertop

3 1/4 X 10

Duct

connection

11 5/8"

(295 mm)

Duct connection

center line

C

Raised vent

center line

Countertop

3 1/4 X 10

Duct

connection

11 3/4"

(298 mm)

Exhaust Locations and Dimensions 

for Remote or In-line Blower Configurations 

(ILHSF and REMP series blowers)

Exhaust Locations and Side Dimensions 

for CABP3 Cabinet blower

Front Exhaust Dimensions 

CABP3 Blower - Bottom Exhaust

Front Exhaust Dimensions 

CABP3 Blower - Right Exhaust

Front Exhaust Dimensions 

CABP3 Blower - Left Exhaust

Содержание RV30

Страница 1: ...ludes installation instructions for optional cabinet blower Dacor model CABP3 Part No 85515 Rev H Use these downdraft raised vents only with approved Dacor cooktops See the installation instructions f...

Страница 2: ...ller In the interest of safety and to minimize problems read these installation instructions completely and care fully before you begin the installation process Leave these installation instructions w...

Страница 3: ...ican Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not c damage electrical wiring and other hi...

Страница 4: ...e connect only one of the specified blowers Warning General Safety Precautions To reduce the risk of fire electric shock serious injury or death when using your appliance follow basic safety precau ti...

Страница 5: ...16 14 mm 3 1 8 79 mm 2 51 mm B A Adjustable anchor legs 1 13 16 46 mm 1 15 16 49 mm 3 16 5 mm Top cap with vent down 7 178 mm 7 1 2 191 mm Front View 15 16 24 mm 28 711 mm to 34 864 mm Tolerances 1 16...

Страница 6: ...atest revision and local codes and ordinances A copy of this standard may be obtained from National Fire Protection Association 1 Batterymarch Park Quincy Massachusetts 02269 9101 Electrical Supply Re...

Страница 7: ...s cooktops a 90 degree elbow must be connected to the cooktop gas inlet see dia gram at right to avoid interference with the raised vent s front panel Installation Specifications Example of Gas Line R...

Страница 8: ...all Exhaust ILHSF series in line blower 3 1 4 X 10 to round transition Duct work Duct work Outside wall Cooktop Wall cap on outside wall Raised vent Raised vent configured for bottom exhaust Floor Wir...

Страница 9: ...0 CFM ILHSF8 600 CFM ILHSF10 1100 CFM REMP3 600 CFM REMP16 1000 CFM Nominal rating at zero inches static pressure see the CABP3 Cabinet Blower Data on page 15 for actual rating Nominal rating at zero...

Страница 10: ...Bottom exhaust configutation with rear or bottom duct routing DUCT DUCT C L CABP3 Cooktop 25 5 8 651 mm Duct connection center line A Raised vent center line Countertop 3 1 4 X 10 Duct connection Duc...

Страница 11: ...l area than the required duct sizes in the table to the right For best performance keep the duct run as short as possible and never exceed the maximums stated at the right The maximum straight duct le...

Страница 12: ...flange 2 keps nuts 1 4 20 PN 83049 2 flat washers 1 4 20 PN 83203 Insulation foam Installation Preparation warning If the electrical service does not meet the Electrical Specifications on page 4 do n...

Страница 13: ...m tape supplied with the raised vent 1 Place the blower on the floor in the orientation it will be mounted on the front of the raised vent Peel the back ing off the tape and attach it to the right and...

Страница 14: ...t surfaces Make sure power to the junction box that will sup 1 ply power to the raised vent is turned off at the circuit breaker or fuse box Remove the screws from the front of the raised vent 2 elect...

Страница 15: ...CABP3 electrical panel Wire nut 3 places To blower Electrical Wiring Remote or In line Blower Installations ILHSF or REMP series REMP series blower shown Floor Raised vent electrical connections see...

Страница 16: ...lower and check for obstructions interfering with the raising mechanism Replace the vent cover or cabinet blower and make sure it is properly centered over the opening on the front of the raised vent...

Страница 17: ...iring Diagram Airflow CFM Cubic feet minute Static pressure inches of water 0 1 0 2 0 3 0 4 0 5 0 100 200 300 400 500 600 CABP3 Blower Performance POWER CONTROL CIRCUIT BOARD TO PUSH BUTTON CIRCUIT BO...

Страница 18: ...16 Notes...

Страница 19: ......

Страница 20: ...Dacor 600 Anton Blvd Suite 1000 Costa Mesa CA 92626 Phone 800 793 0093 Fax 626 403 3130 www Dacor com...

Отзывы: