ENGLISH
82
GB
The other menu pages vary with the associated functions and are de
-
The other menu pages vary with the associated functions and are de
-
scribed later by type of indication or setting. Once you have entered any
scribed later by type of indication or setting. Once you have entered any
menu, the bottom of the page always shows a summary of the main oper
-
menu, the bottom of the page always shows a summary of the main oper
-
ating parameters (running status or any fault, current speed and pressure).
ating parameters (running status or any fault, current speed and pressure).
This allows a constant view of the machine’s fundamental parameters
This allows a constant view of the machine’s fundamental parameters..
Indications on the status bar at the bottom of each page
Identifying code
Description
GO
Motor stopped
SB
Motor stopped
Disable
Motor status manually disabled
rpm
Motor revs per minute
bar
Plant pressure
FAULT
Presence of an error preventing operation of the electropump
The following may appear on the pages that show parameters: numerical
The following may appear on the pages that show parameters: numerical
values and units of measure of the current item, values of other parameters
values and units of measure of the current item, values of other parameters
linked to the setting of the current item, graphic bar, lists; see Figure 15.
linked to the setting of the current item, graphic bar, lists; see Figure 15.
Figure 15: Display of a menu parameter
Table 10: Indications on the status bar
6.4 - Blocking parameter setting by Password
6.4 - Blocking parameter setting by Password
The device has a password-enabled protection system. If a password is
The device has a password-enabled protection system. If a password is
set, the parameters of the device will be accessible and visible but it will
set, the parameters of the device will be accessible and visible but it will
not be possible to change them.
not be possible to change them.
The password management system is in the “technical assistance” menu
The password management system is in the “technical assistance” menu
and is managed by means of the parameter PW
and is managed by means of the parameter PW
6.5 - Enabling and disabling the motor
6.5 - Enabling and disabling the motor
In normal operating conditions, pressing and then releasing both the “+”
In normal operating conditions, pressing and then releasing both the “+”
and “-” keys causes the blocking/release of the motor (self-holding even
and “-” keys causes the blocking/release of the motor (self-holding even
after switching off). If there is a fault alarm, the operation described above
after switching off). If there is a fault alarm, the operation described above
resets the alarm.
resets the alarm.
When the motor is disabled this status is shown by the blinking white LED.
When the motor is disabled this status is shown by the blinking white LED.
This command can be activated from any menu page except RF and PW.
This command can be activated from any menu page except RF and PW.
7 - MEANING OF THE INDIVIDUAL PARAMETERS
7 - MEANING OF THE INDIVIDUAL PARAMETERS
7.1 - User Menu
7.1 - User Menu
From the main menu, pressing the MODE key (or using the selection menu
From the main menu, pressing the MODE key (or using the selection menu
and pr o - ), gives access to the USER MENU. In the menu the
and pr o - ), gives access to the USER MENU. In the menu the
MODE key allows you to scroll through the various menu pages. The val
-
MODE key allows you to scroll through the various menu pages. The val
-
ues shown are the following.
ues shown are the following.
7.1.1 - Status:
7.1.1 - Status:
Displays the pump status.
Displays the pump status.
7.1.2 - RS: Rotation speed display
7.1.2 - RS: Rotation speed display
Motor rotation speed in rpm.
Motor rotation speed in rpm.
7.1.3 - VP: Pressure display
7.1.3 - VP: Pressure display
Plant pressure measured in [bar] or [psi] depending on the measuring sys
-
Plant pressure measured in [bar] or [psi] depending on the measuring sys
-
tem used.
tem used.
7.1.4 - VF: Flow display
7.1.4 - VF: Flow display
Displays the instantaneous flow in [litres/min] or [gal/min] depending on the
Displays the instantaneous flow in [litres/min] or [gal/min] depending on the
set measuring system.
set measuring system.