DWS-3160 Series Gigabit Ethernet Unified Switch CLI Reference Guide
594
Format
create sflow analyzer_server <value 1-4> owner <name 16> {timeout [<sec 1-2000000> |
infinite] | collectoraddress <ipaddr> | collectorport <udp_port_number 1-65535> |
maxdatagramsize <value 300-1400>}
Parameters
analyzer_server
- The ID of analyzer server.
<value 1-4>
- Enter the analyzer server ID here.
owner
- The entity making use of this sFlow analyzer_server. When owner is set or modified, the
timeout value will become 400 automatically.
<name 16>
- Enter the owner name here. This name can be up to 16 characters long.
timeout
- (Optional) The seconds to wait before the server is timed out. When the analyzer
server times out, all of the flow samplers and counter pollers associated with this analyzer
server will be deleted. The default value is 400 seconds.
<sec 1-2000000>
- Enter the time-out value here. This value must be between 1 and 2000000
seconds.
infinite
- Indicates the analyzer server never timeout.
collectoraddress
- (Optional) The IP or IPv6 address of the analyzer server. If this is set to 0 or
not specified, the IP address is 0 and the entry is not active.
<ipaddr>
- Enter the IP address used for the configuration here.
collectorport
- (Optional) The destination UDP port for sending the sFlow datagram. If not
specified, the default value is 6364. The specified UDP port number can NOT conflict with
other applications.
<udp_port_number 1-65535>
- Enter the destination UDP port number here. This value must
be between 1 and 65535.
maxdatagramsize
- (Optional) The maximum number of data bytes that can be packed in a
single sample datagram. If not specified, the default value is 1400 bytes.
<value 300-1400>
- Enter the maximum datagram size here. This value must be between 300
and 1400.
Restrictions
Only Administrators and Operators can issue this command.
Example
To create the analyzer server:
DWS-3160-24PC:admin# create sflow analyzer_server 2 owner monitor timeout
infinite collectoraddress 10.0.0.1 collectorport 65524 maxdatagramsize 300
Command: create sflow analyzer_server 2 owner monitor timeout infinite
collectoraddress 10.0.0.1 collectorport 65524 maxdatagramsize 300
Success.
DWS-3160-24PC:admin#
64-8
config sflow analyzer_server
Description
This command is used to configure the receiver information. The user can specify more than one
collector with the same IP address if the UDP port numbers are unique.
Содержание DWS-3160 Series
Страница 1: ......
Страница 13: ...DWS 3160 Series Gigabit Ethernet Unified Switch CLI Reference Guide 9 R refresh the displayed pages ...
Страница 271: ...DWS 3160 Series Gigabit Ethernet Unified Switch CLI Reference Guide 267 ...
Страница 586: ...DWS 3160 Series Gigabit Ethernet Unified Switch CLI Reference Guide 582 ...
Страница 766: ...DWS 3160 Series Gigabit Ethernet Unified Switch CLI Reference Guide 762 ...