DWS-3160 Series Gigabit Ethernet Unified Switch CLI Reference Guide
598
DWS-3160-24PC:admin#show sflow
Command: show sflow
sFlow Version : V5
sFlow Address : 10.90.90.90
sFlow State : Enabled
DWS-3160-24PC:admin#
64-13
show sflow flow_sampler
Description
This command is used to display the sFlow flow sampler configured for ports. The actual value
rate is 256 times the displayed rate value. There are two types of rates. The Configured Rate is
configured by the user. In order to limit the number of packets sent to the CPU when the rate of
traffic to the CPU is high, the sampling rate will be decreased. This is specified as the active rate.
Format
show sflow flow_sampler
Parameters
None.
Restrictions
Only Administrators, Operators and Power-Users can issue this command.
Example
To display the sFlow flow sampler information of ports which have been created:
DWS-3160-24PC:admin#show sflow flow_sampler
Command: show sflow flow_sampler
Port Analyzer Server ID Configured Rate Active Rate Max Header Size
---- ------------------ --------------- ----------- ---------------
1 1 0 0 18
Total Entries: 1
DWS-3160-24PC:admin#
64-14
show sflow counter_poller
Description
This command is used to display the sFlow counter pollers which have been configured for port.