DWS-3160 Series Gigabit Ethernet Unified Switch CLI Reference Guide
593
Example
To configure the interval of sFlow counter poller port 1 to be 0:
DWS-3160-24PC:admin# config sflow counter_poller ports 1 interval disable
Command: config sflow counter_poller ports 1 interval disable
Success.
DWS-3160-24PC:admin#
64-6
delete sflow counter_poller
Description
This command is used to delete an sFlow counter poller from a specified port.
Format
delete sflow counter_poller ports [<portlist> | all]
Parameters
ports
- Specifies the list of ports to delete the counter poller.
<portlist>
- Enter the list of ports that will be used for this configuration here.
all
- Specifies all ports on the Switch.
Restrictions
Only Administrators and Operators can issue this command.
Example
To delete sFlow counter poller on port 1:
DWS-3160-24PC:admin# delete sflow counter_poller ports 1
Command: delete sflow counter_poller ports 1
Success.
DWS-3160-24PC:admin#
64-7
create sflow analyzer_server
Description
This command is used to create the analyzer server. The user can specify more than one analyzer
server with the same IP address but with different UDP port numbers. You can have up to four
unique combinations of IP addresses and UDP port numbers.
Содержание DWS-3160 Series
Страница 1: ......
Страница 13: ...DWS 3160 Series Gigabit Ethernet Unified Switch CLI Reference Guide 9 R refresh the displayed pages ...
Страница 271: ...DWS 3160 Series Gigabit Ethernet Unified Switch CLI Reference Guide 267 ...
Страница 586: ...DWS 3160 Series Gigabit Ethernet Unified Switch CLI Reference Guide 582 ...
Страница 766: ...DWS 3160 Series Gigabit Ethernet Unified Switch CLI Reference Guide 762 ...