
DGS-3700 Series Layer 2 Managed Gigabit Ethernet Switch CLI Reference Guide
Page | 16
DGS-3700-12:5#config ddm log enable
Command: config ddm log enable
Success.
DGS-3700-12:5#
config ddm trap
Purpose
To enable or disable trap action when the SFP exceed its DDM threshold.
Syntax
config ddm trap [enable | disable]
Description
This command is used to configure the DDM trap action when encountering an
exceeding alarm or warning threshold event.
Parameters
trap
- Specify whether or not to send a trap when the operating parameter exceeds the
corresponding threshold.
enable
- Enable the parameter selected.
disable
- Disable the parameter selected.
Restrictions
Only Administrator and Operator-level users can issue this command.
Example usage:
To configure the DDM trap state to enable:
DGS-3700-12:5#config ddm trap enable
Command: config ddm trap enable
Success.
DGS-3700-12:5#
config ddm ports
Purpose
To configure a DDM threshold or action.
Syntax
config ddm ports [<portlist> | all] [[temperature_threshold | voltage_threshold |
bias_current_threshold | tx_power_threshold | rx_power_threshold]
{high_alarm <float> | low_alarm <float> | high_warning <float> |
low_warning <float>} (1) | {state [enable | disable] | shutdown [alarm |
warning | none]} (1)]
Description
This command is used to configure a DDM threshold or action.
Parameters
<portlist>
- Specify a range of ports to be configured.
all
- Specify to configure all ports.
temperature_threshold
- Specify the temperature thresholds of the specified ports.
voltage_threshold
- Specify the voltage thresholds of the specified ports.
bias_current_threshold
- Specify the bias current thresholds of the specified ports.
tx_power_threshold
- Specify the output power thresholds of the specified ports.
rx_power_threshold
- Specify the received power thresholds of the specified ports.
high_alarm
- Specify high threshold for alarm. For the temperature threshold: when
the operating parameter rises above this value, action associated with alarm is
taken. The range of this parameter is -128 to 127.996 Celsius degrees. For the
voltage threshold: when the operating parameter rises above this value, action
associated with alarm is taken. The range of this parameter is 0 to 6.55 voltages.
For the bias current threshold: when the operating parameter rises above this value,
action associated with alarm is taken. The range of this parameter is 0 to 131 mA.
For the output power threshold: when the operating parameter rises above this
value, action associated with alarm is taken. The range of this parameter is 0 to