___________________________________________________
CXR Larus 80-100-400 Issue 2 July 2006 page
3-13
a. Output to track and hold clock card through system backplane; 1.544 MHz
square wave with 50% duty cycle.
b. Output to output driver cards through system backplane; 1.544 MHz
differential square wave with 50% duty cycle.
c. Alarm signal to 54560 Alarm Interface Card
d. One-wire interface to 54550 Information Management Card to report
personality (Model, List, Issue, revisions, Larus serial number, customer
inventory control information, and other customer designated data), LED
status, and slot ID.
e. Front panel monitor jack for active input signal.
f. Serial communication path through system backplane to/from track and
hold clock card for status report and input configuration.
3.3391 LED
Indicators:
Front Panel Label LED Color Indication
FAIL Red
Card
fail
I/P A
Green
Input A selected
I/P B
Green
Input B selected
PULSES
Green
PLL oscillator in working condition
I/P FAULT
Yellow
Internal fault
LOS
Red
Loss of signal (LOS) (no clock recovery) or loss of
frame (LOF), including the alarm indication signal
(AIS)
3.3392 Card
Power:
-48 volts, 40 mA (nominal)
3.3393 Power
Fuse:
0.75 amp, Type GMT
3.3394 Fuse
Alarm:
Closure to battery
Содержание 54500-16
Страница 7: ...This page is intentionally left blank...
Страница 28: ..._______________________________________________________________ CXR Larus 80 100 400 Issue 2 July 2006 2 3...
Страница 29: ...CXR Larus 80 100 400 2 4 Issue 1 July 2006 ______________________________________________________________...
Страница 30: ..._______________________________________________________________ CXR Larus 80 100 400 Issue 2 July 2006 2 5...
Страница 31: ...CXR Larus 80 100 400 2 6 Issue 1 July 2006 ______________________________________________________________...
Страница 39: ...This page is intentionally left blank...
Страница 205: ...__________________________________________________________ 5 77...
Страница 214: ...AB 2 This page is intentionally left blank...