CXR Larus 80-100-400
Issue 1, July 2006
______________________________________________________________
____________________________________________________________
5−
16
g. The green ACTIVE LED indicates that the unit is being selected to drive
the outputs.
h. The seven segment display indicates the STATUS of the input failure.
i. The HOLD TEST pushbutton causes the microcontroller to execute a
diagnostic routine and display 'H' if successful. The unit returns to normal
tracking in a few seconds. (An internal TEST/RUN toggle, S2, is set in
RUN mode for normal operation.)
5.5219 Alarm
Output
The HOLD or FAIL condition, or a fault reported by the crystal oscillator,
results in a card alarm output to the 54560 Alarm Interface Card and to the
54550 Information Management Card. A data link to the 54550 card allows
the 54522 card to report its status (tracking, hold, stand-alone, or failed) as
well as control, personality and, with DS1 only, sync messaging data.
5.5220 Clocks A and B
Each of the two 54522 cards in a redundant system drives a Clock A or B
differential clock bus to the ten output card slots. Each card also drives a hold
indicator bus. Selection of the A or B clock is done automatically by logic
circuitry on the output cards; it can be changed manually from a terminal
connected to the 54550 Information Management Card.
5.5221 External 5 or 10 MHz Signal
In addition to the DS1/E1 inputs, the external 5 or 10 MHz signal may also be
selected as a tracking input. Selection is done manually by TL1 or Menu user
command through the interfaces of the 54550 Information Management Card.
Once an external signal has been selected as the tracking reference, the clock
card will stay on it until the user issues a different command. If the signal is
bad during external signal tracking, the clock card will enter the HOLD mode
until the signal recovers. However, the clock card will not go back to tracking
DS1/E1 inputs unless told to do so by command issued via the 54550 card.
5.5222 Monitor
Jack
A front panel DS1/E1 monitor jack (-20 dB referenced to the input) provides
framed all ones at the clock output frequency.
5.5223 One-wire
Interface
A one-wire interface communicates to the 54550 Information Management
Card that the 54522 is installed.
5.5224 Synchronization Status Messages (DS1 with ESF only)
When a synchronization status message (SSM) is received, the active 54522
Содержание 54500-16
Страница 7: ...This page is intentionally left blank...
Страница 28: ..._______________________________________________________________ CXR Larus 80 100 400 Issue 2 July 2006 2 3...
Страница 29: ...CXR Larus 80 100 400 2 4 Issue 1 July 2006 ______________________________________________________________...
Страница 30: ..._______________________________________________________________ CXR Larus 80 100 400 Issue 2 July 2006 2 5...
Страница 31: ...CXR Larus 80 100 400 2 6 Issue 1 July 2006 ______________________________________________________________...
Страница 39: ...This page is intentionally left blank...
Страница 205: ...__________________________________________________________ 5 77...
Страница 214: ...AB 2 This page is intentionally left blank...