P/N IM-C35KD Rev. C
2014 Commercial Wireless Systems International, LLC.
76
continue the survey. Once an acceptable location has been determined, hold the repeater at this
location and continue to test devices for locations that result in acceptable surveys. When the range
of this repeater has been exhausted, continue to test and add repeater locations as described until a
good survey result is achieved for all the devices in the installation.
8.2 Existing Installation Survey
To check the signal of an existing device in an installation, momentarily place a magnet in the
appropriate survey location of the device. Refer to the device manual for the survey location of each
type of transmitter. One beep should be heard at the device and the repeater which received the
survey signal followed by either a single beep or two beeps at the device only. A single beep
indicates an unacceptable survey and two beeps indicate an acceptable survey. If an unacceptable
survey is the result, the device will have to be relocated or a repeater added to receive it at this
location. To test repeater to repeater communications, press the survey button located on the
repeater circuit board for 1 second then release. Refer to figure 4 for the survey button location. The
beeps that indicate the survey start and result are the same as a device. The repeater which received
the survey signal will beep once. This is to notify the installer which repeater is responding to the
device survey signal.