Chapter 5: CPU Operation and Memory
65
Note:
Channel: The inherent number of the timer and the counter.
Set Value (SV): The designated value for the timer (to turn On) and the counter (number of
times On) to start operation.
Present Value (PV): Current processing value of the timer (elapsed time) and the counter
(number of counts).
Note:
When using GPC software, the above W registers can be represented as follows.
Ch
Set Value (SV)
Present Value (PV)
0
W2048 = SV0
W2304 = PV0
1
W2049 = SV1
W2305 = PV1
:
:
:
255
W2303 = SV255
W2559 = PV255
Where SV is Set Value and PV is Present Value.
CAUTION:
Be sure you understand the programming of the timer/counter thoroughly. If you
change the above registers while the program is running or program them
incorrectly, errors or damage may occur.