Chapter 6: Instructions
151
Example
Program Expression
Operation Results
When R0.0 is On, get Ch = 2 (R2 word) immediately
from the external input.
If R0.1 is On, send out Ch = 3 (R3 word)
immediately to the external output.
For this example, R2 is an external input module, and
R3 is an external output module.
INPR
Ch = 2
OUTR
Ch = 3
R0.0
R0.1
Normal
Operation
Read Inputs
Program
Update
Outputs
INPR/OUTR
Example
Read Inputs
Program
Read R2 Input
Update R3
Output
Update
Outputs