n
CORRECTION LEVEL
N. OF ERROR CORRECTION CODE WORD
48
Error correction level 0
2
49
Error correction level 1
4
50
Error correction level 2
8
51
Error correction level 3
16
52
Error correction level 4
32
53
Error correction level 5
64
54
Error correction level 6
128
55
Error correction level 7
256
56
Error correction level 8
512
• Error correction level speci
fi
ed by "ratio" (m = 49) is as follows. The error correction
level is de
fi
ned by the calculated value [number of data code word × n × 0.1 = (A)]. The
number of the error correction code word is changeable in proportion to the number of
the code words on the data area.
CALCULATED
VALUE (A)
CORRECTION LEVEL
N. OF ERROR CORRECTION
CODE WORD
0 - 3
Error correction level 1
4
4 - 10
Error correction level 2
8
11 - 20
Error correction level 3
16
21 - 45
Error correction level 4
32
46 - 100
Error correction level 5
64
101 - 200
Error correction level 6
128
201 - 400
Error correction level 7
256
> 400
Error correction level 8
512
• Settings are effective until ESC @ is executed, the printer is reset or the power is turned
off.
[Default]
m = 49, n = 1 [ratio: 10%]
[Reference]
$1D $28 $6B
[Example]
$1D $28 $6B [function 069]
Printers: KPM300
VeriPrint
, KUBE II
VeriPrint
, KUBE-L
VeriPrint
, TK300II
VeriPrint
[Name]
Specify the error correction level (AZTEC)
[Format] ASCII
GS
(
k
pL
pH
cn
fn
n
Hex
1D 28 6B pL pH cn
fn n
Decimal
29 40 107 pL pH cn
fn n
[Range]
(pL+pH × 256) = 4
(pL = 4, pH = 0)
cn = 52
fn = 69
0
≤
n
≤
4
[Description] Speci
fi
es the ECC level (Error Correction Capacity) of AZTEC symbol.
ESC/POS™ Emulation
48
Command Reference
Содержание KPM300