$1C $80
Printers: KPM300
VeriPrint
, KUBE II
VeriPrint
, KUBE-L
VeriPrint
, TK300II
VeriPrint
[Name]
Read date/time of the real time clock
[Format] ASCII
FS
{
}
m
Hex
1C
80
m
Decimal
28
128
m
[Range] 0
≤
m
≤
3
[Description]
Read date/time of the real time clock in the format speci
fi
ed by m values as follows:
m
FORMAT
0
DD/MM/YY hh:mm:ss
1
DDMMYYhhmmss
2
YYMMDDhhmmss
3
YYMMDDkkmmssd
where:
DD =
represents the day of the date
MM =
represents the month of the date
YY =
represents the year of the date
hh =
represents the hour of the time
mm =
represents the monutes of the time
ss =
represents the seconds of the time
d =
represents the day of the wee
[Notes]
• Before send the date/time, if the m parameter is valid the printer transmits the ACK ($06)
followed by the number of bytes to sent, otherwise return NACK ($015).
[Default]
[Reference]
[Example]
To read date/time in the “DDYYMMhhmmss” format, transmit:
Host
HEX
$1C $80
$01
ASCII
FS
{ }
m
For example if the current date/time are “15 September 2006 at 10:56:20 (AM)” the
printer’s answer is as follows:
HEX
$06
$0C $31 $35 $30 $39 $30 $36 $31 $30 $35 $36 $32 $30
ASCII
ACK
FF
1
5
0
9
0
6
1
0
5
6
2
0
ESC/POS™ Emulation