3 — PROGRAMMABLE PARAMETERS:
BDI
BDI% will automatically reset to 100%. The reset voltage value can be set from
the programmed Full Volts value up to 3.00 VPC, in 0.01 VPC increments.
BATTERY ADJUST
The
battery adjustment
parameter is used to adjust the BDI algorithm to
compensate for battery capacity. Higher capacity batteries can spend more time
below the Full Volts setting before beginning to lose charge. The battery
adjustment parameter sets the number of seconds of droop required before the
battery state of charge is decremented by 1%. It is adjustable from 0.1 to 20.0
seconds.
BDI DISABLE
The
BDI disable
parameter, when programmed On, limits the vehicle
’
s maxi-
mum speed to the BDI Limit Speed when the battery state-of-charge is 0%.
BDI LIMIT SPEED
The
BDI limit speed
parameter sets the vehicle
’
s maximum allowed speed when
the BDI disable parameter is programmed On and the battery state of charge is
0%. The BDI limit speed is adjustable from 0 to 100% of drive output.
If the BDI disable parameter is programmed Off, the BDI limit speed will
not be in effect.
Table 5
STANDARD BATTERY VOLTAGES
FOR FLOODED LEAD ACID AND SEALED MAINTENANCE-FREE BATTERIES
24V BATTERY
36V BATTERY
PARAMETER
FLOODED
SEALED
FLOODED
SEALED
Full volts
24.5 V
24.5 V
36.7 V
36.7 V
(2.04
×
12)
(2.04
×
12)
(2.04
×
18)
(2.04
×
18)
Empty volts
20.9 V
22.9 V
31.3 V
34.4 V
(1.74
×
12)
(1.74
×
12)
(1.91
×
18)
(1.91
×
18)
Reset volts
25.2 V
25.2 V
37.8 V
37.8 V
(2.10
×
12)
(2.10
×
12)
(2.10
×
18)
(2.10
×
18)
Note: To convert VPC to the actual Full, Empty, or Reset voltage,
multiply the VPC by 12 for 24V systems or by 18 for 36V systems.