Curtis 1243
GEN
2 Manual
66
6 — PROGRAMMER MENUS:
Program Menu
Program Menu,
cont’d
M2 MAX REV SPD
Mode 2 maximum reverse speed, as % drive output
M3 MAX REV SPD
Mode 3 maximum reverse speed, as % drive output
M4 MAX REV SPD
Mode 4 maximum reverse speed, as % drive output
CREEP SPEED
Creep speed, as % drive output
THROTTLE TYPE
Type of throttle input
1
THRTL DEADBAND
Throttle neutral deadband, as %
THROTTLE MAX
Throttle input req
’
d for 100% drive output, as %
THROTTLE MAP
Drive output at 50% throttle input, as %
FIELD MIN
Minimum
fi
eld current, in amps
FIELD MAX
Maximum
fi
eld current, in amps
FLD MAP START
Armature current at which
fi
eld map takes effect, in amps
FIELD MAP
Field current map setting, as %
CURRENT RATIO
Current ratio: factor of 1, 2, 4, or 8
M1 RESTRAINT
Mode 1 restraint braking, in amps
M2 RESTRAINT
Mode 2 restraint braking, in amps
M3 RESTRAINT
Mode 3 restraint braking, in amps
M4 RESTRAINT
Mode 4 restraint braking, in amps
LOAD COMP
Load compensation: 0 to 25% drive output
HPD
High pedal disable (HPD) type
2
SRO
Static return to off (SRO) type
3
SEQUENCING DLY
Sequencing delay, in seconds
MAIN CONT INTR
Main contactor uses interlock input: On or Off
MAIN OPEN DLY
Main contactor open delay: On or Off
CONT DIAG
Contactor diagnostics: On or Off
AUX TYPE
Auxiliary driver type
4
AUX DELAY
Auxiliary driver open delay, in seconds
EMR REV C/L
Emergency reverse current limit, in amps
EMR REV CHECK
Emergency reverse wiring check: On or Off
EMR DIR INTR
Emergency reverse direction interlock: On or Off
VARIABLE BRAKE
Variable braking: On or Off
ANTI-TIEDOWN
Anti-tiedown: On or Off
POT LOW FAULT
Pot Low fault: On or Off
FULL VOLTS
Voltage considered 100% state of charge, in volts
EMPTY VOLTS
Voltage considered 0% state of charge, in volts
RESET VOLTS
Voltage at which state of charge resets to 100%, in volts
BATTERY ADJUST
BDI algorithm adjustment to compensate for battery capacity, in secs
BDI LOCKOUT
Fault 2 output high when BDI%=0: On or Off
BDI DISABLE
Battery s-o-c <1% invokes BDI Limit Speed: On or Off