Curtis 1243
GEN
2 Manual
20
3 — PROGRAMMABLE PARAMETERS
Battery Parameter
......................
p.21
Battery Voltage
Acceleration Parameters
............
p.21
Drive Current Limit, M1–M4
Acceleration Rate, M1–M4
Quick Start
Current Ratio
Braking Parameters
...................
p.23
Braking Current Limit, M1–M4
Deceleration Rate, M1–M4
Throttle Deceleration Rate
Restraint, M1–M4
Braking Rate, M1–M4
Taper Rate
Variable Braking
Interlock Braking
Parameters
...................................
p.26
Interlock Braking Rate
Max. Forward Regen
Max. Reverse Regen
Min. Forward Regen
Min. Reverse Regen
Max. Load Volts
Min. Load Volts
Electromagnetic Brake
Parameters
...................................
p.28
Auxiliary Driver Type
Electromagnetic Brake PWM
Auxiliary Driver Delay
Interlock Brake Delay
Speed Parameters
.......................
p.31
Max. Forward Speed, M1–M4
Max. Reverse Speed, M1–M4
Creep Speed
Load Compensation
Throttle Parameters
...................
p.32
Throttle Type
Throttle Deadband
Throttle Max
Throttle Map
Pot Low Fault
Field Parameters
.........................
p.38
Min. Field Current Limit
Max. Field Current Limit
Field Map Start
Field Map
Field Check
Main Contactor Parameters
.....
p.40
Main Contactor Interlock
Main Contactor Open Delay
Main Contactor Diagnostics
Sequencing Fault Parameters
...
p.41
Anti-Tiedown
High Pedal Disable (HPD)
Static Return to Off (SRO)
Sequencing Delay
Emergency Reverse
Parameters
...................................
p.43
Emerg. Reverse Current Limit
Emerg. Reverse Check
Emerg. Reverse Direction Interlock
Motor Protection Parameters
...
p.44
Warm Speed
Motor Warm Resistance
Motor Hot Resistance
Motor Resistance Compensation
Hourmeter
Parameters
....................
p.45
Adjust Hours High
Adjust Hours Middle
Adjust Hours Low
Set Total Hours
Set Traction Hours
Total Service Hours
Traction Service Hours
Total Disable Hours
Traction Disable Hours
Traction Fault Speed
Service Total
Service Traction
Hourmeter Type
Pump Meter
BDI Parameters
...........
p.49
Full Voltage
Empty Voltage
Reset Voltage
Battery Adjust
BDI Disable
BDI Limit Speed
Fault Code
Parameters
....................
p.51
Fault Code
BDI Lockout
Individual parameters are described in the following text in
the order they are listed on this page. They are listed by the
abbreviated names that are displayed in the programmer
’
s
Program Menu. Not all of these parameters are displayed
on all controllers; the list for any given controller depends
on its speci
fi
cations.
The programmer displays the parameters in a different
order. For a list of the individual parameters in the order in
which they appear in the Program Menu, see Section 6:
Programmer Menus.
☞