Curtis 1243
GEN
2 Manual
48
3 — PROGRAMMABLE PARAMETERS:
Hourmeters
HOURMETER TYPE
The Spyglass gauge displays hourmeter data for 5 seconds each time the
keyswitch is turned on. The
hourmeter type
parameter de
fi
nes whether the
total hourmeter or traction hourmeter data will be displayed. When this
parameter is programmed On, the total hourmeter is displayed; when pro-
grammed Off, the traction hourmeter is displayed.
PUMP METER
The
pump meter
parameter, when programmed On, con
fi
gures the Fault
Output 1 line (at Pin 2) to function as an input to measure the hours a pump
is running. The pump is considered to be running when Pin 2 is at the battery
voltage. When the pump meter parameter is programmed On, the traction
hourmeter serves as a combination traction/pump hourmeter, and all the above
“
TRAC
”
hourmeter parameters apply to both traction hours and pump hours.
The traction/pump hourmeter counts the hours when a direction is selected and
the hours when the pump is running.
Other Hourmeter Parameters