AIR INLET CONTROL
If air inlet modules are used, the user can make individual probe assign-
ments for each air inlet. In addition, a compensation can be applied to
the air inlet opening calculated by the air inlet module, based on the
temperature difference between the average Expert-50 room tempera-
ture and the average of the probes assigned to control the air inlet. Up to
12 air inlet modules can be connected to the Expert-50 (the number of
inlets used is configured in SETUP OUTPUTS).
Inlets' reference numbers that used by the Expert-50 do not correspond
to the ID numbers that are used by the air inlet modules. This is because
ID numbers 1, 2 and 3 of air inlet modules are reserved. ID numbers
should be assigned as follows:
Making Probes Assignments for Inlet Control
The air inlet module uses the average temperature of the probes as-
signed to the inlet.
Set the function to SETTINGS-INLETS using the menu select buttons.
The probe assignments for inlet 1 are displayed. The flashing probes
are the ones assigned for controlling the inlet.
Press the Edit key to change the as-
signment status of the first probe.
Use the arrow keys to set the probe
to ON or OFF.
Press the Edit key to change the assignment status of the other
probes.
Inlet 1 Probes
1 2 3 4 5 6
Inlets' ID #
on the Expert-50
Inlets' ID #
on the air inlet module
1
4
2
5
...
...
12
15