32
Expert-50 rev.10
Expert-50
Adjusting Heater Compensation Level
When the relative humidity reaches this value, all heater outputs are acti-
vated according to the timer cycle defined below. The heaters are turned
off when the room temperature exceeds the stage 2 start temperature
minus one half the start-stop temperature differential.The humidity level
can be adjusted from 0 to 100%.
Set the function to
SETUP-
HUMIDITY COMPENSATION
using
the menu select buttons. The
humidity compensation parameters
are displayed, depending on which
compensation mechanisms are
enabled.
Press the down-arrow key until the appropriate parameter is displayed
Press the Edit key. The humidity
level for activating the heaters
flashes on the display.
Use the arrow keys to adjust the humidity level to the desired value.
Adjusting Heater Timer Cycle
This timer cycle is used to operate the heaters for humidity compensation.
The on time and cycle time can be adjusted from 0 to 99 minutes, 59 sec.
Set the function to
SETUP-
HUMIDITY COMPENSATION
using the menu select buttons.
The humidity compensation
parameters are displayed, depending on which compensation mecha-
nisms are enabled.
min. vent. comp.
50% at 70% RH
min. vent. comp.
50% at 70% RH
hum.comp. heat
at: 20% RH