Output Setup
1. Number of Heaters and Fan
Stages:
Press the Edit key to adjust
the number of heaters used. Press
the Edit key once again to adjust the
number of fan stages.
2. Number of Clock Outputs/Tunnel
Ventilation :
Press the Edit key to set
the number of clock outputs used.
Press the Edit key once again to
enable or disable tunnel ventilation.
3. Number of Inlets :
Press the Edit
key to set the number of air inlet
modules.
4. Heater Probes on Heaters 1 - 8 :
Use the adjustment knob to select a
heater stage. The probes assigned to
the heater appear flashing on the dis-
play. Press the Edit key and use the arrow keys to enable or disable each
probe individually for the heater. Press the down-arrow key to configure
the relays for each heater (see below).
When the down-arrow key is pressed at this point, the LED of the last
heater configured above flashes and the probe assignments for that heater
are displayed. The user can now configure each output separately by
selecting the output using the output select buttons and adjusting the pa-
rameters displayed. Configuration parameters vary according to the type
of output. For example, probes are assigned when configuring a heater
stage. Use the up- and down-arrow keys to step through all the display
screens for a given output. The last display screen for all outputs is the
relay assignment.
#Heaters: 8
#Fan stages: 15
#Clocks: 4
Use tunnel? YES
#Inlets 12
Heater 8 Probes
1 2 3 4