24
Expert-50 rev.10
TIME AND DATE FUNCTIONS
Setting the Time and Date
Set the function to
TIME & DATE
using the menu select buttons.
The current time and date are
displayed.
Press the Edit key. The hours value flashes. Use the arrow keys to
set the hours. Press the Edit key. The minutes value flashes. Use
the arrow keys to set the minutes. When the minutes value is
adjusted, the seconds are set to zero.
Press the Edit key. The year flashes. Use the arrow keys to set the
year. Press the Edit key. The month flashes. Use the arrow keys to
set the month. Press the Edit key. The day flashes. Use the arrow
keys to set the day to the appropriate value.
Setting the Herd Age
The herd age is used by the temperature and minimum ventilation
curves, as well as for tunnel ventilation.
Set the function to
AGE
using the menu select buttons. The current
herd age is displayed.
Press the Edit key. The age value
flashes on the display.
Use the arrow keys to set the age to the desired value.
12:49.53 PM
03/15/2000
Age: 24 days
Содержание EXPERT-50
Страница 1: ...Expert 50 Temperature Controller USER S MANUAL M 890 00075 rev 10 REV 01...
Страница 2: ......
Страница 57: ...NOTES NOTES...