12
Expert-50 rev.10
CONTROLLER SETUP
The following section describes how to customize the controller for your
particular application. Normally, this setup needs to be done only once.
Setup parameters are grouped under two functions: USER and OUT-
PUTS. The USER setup is used for configuring display units, probe
inputs, humidity compensation, the fan differential, etc. The OUTPUTS
setup is used for configuring the outputs.
The parameters are presented below in the order they appear on the
display. Press the down-arrow key to step to the next parameter. Press
the Edit key and use the arrow keys to adjust a parameter value. When
you are finished adjusting a parameter, press the Edit key to return to
display mode or move to the next parameter. The user should step
through all the parameters under these two functions at least once.
USER SETUP
1. Display Contrast and Backlight:
Press the Edit key to adjust the display
contrast. Press the Edit key once again
to turn the display backlight on or off.
Note that the backlight is automatically
turned off after 5 minutes of inactivity
even if it is turned on. It is turned on
again when a key is pressed.
2. Time of Day Format:
Press the Edit
key to select either AM-PM or 24H time.
3. Number of Temperature Probes in
the Room:
Press the Edit key to set the
number of room temperature probes
wired in the controller (whether they are
selected or not). Note that probes must
be wired from left to right following the
numerical order of the terminals on the
board if 4 probes are not needed.
Contrast: 11
Backlight: YES
Time of day
format: AM-PM
# T° sensors
in the room : 4
Содержание EXPERT-50
Страница 1: ...Expert 50 Temperature Controller USER S MANUAL M 890 00075 rev 10 REV 01...
Страница 2: ......
Страница 57: ...NOTES NOTES...