21
Expert-50 rev.10
Expert-50
The user can define a temperature curve to adjust the set point auto-
matically over a given time period.
Temperature Curve
A curve is defined using up to 10 points. Each point specifies a day number
and a set point for that day. The herd age value defines the current day
number used by the curve. Once the points of the curve are defined, the
curve must be activated. The controller will change the temperature set
point every hour in a linear fashion between consecutive points of the
curve. When the last point of the curve is reached, the temperature set
point for that day is maintained until the herd age is adjusted for starting a
new herd or the set point is adjusted manually.
NOTES:
i)
All ten points of the curve must be specified. If ten points are not
needed, repeat the last temperature value for each unnecessary
point.
ii) Certain restrictions apply to reduce the risk of errors:
- The highest possible day number is 250.
- Decreasing day numbers are not allowed.
- Increasing temperatures are not allowed.
Temperature
Days
T
o
1
T
o
2
T
o
3
T
o
4
T
o
5
T
o
6
d4
d25
d35
d50
d70
d80
○○○○○○○○
○
○
○○○○○
○○○○
○○○○○○
○
○
○
○
○○○○
○○○○
○
○○○○