![CTC Union GSi 16 Скачать руководство пользователя страница 92](http://html1.mh-extra.com/html/ctc-union/gsi-16/gsi-16_installation-and-maintenance-manual_2693361092.webp)
92
CTC GSi 16
Charging EHS-tank
Charge start diff temp °C
7
Charge stop diff temp °C
3
Charge tank temp °C
60
-Max permitted brine temp °C
18 (1—30)
Setting for the maximum permitted brine temperature.
Charging of the borehole ceases when this value has
been reached.
12.11.7 Charging EHS-tank
This function concerns charging conditions between
EcoTank and EHS-tank in solar system 2.
This function CANNOT be combined with the “Diff
thermostat function”.
Charge start diff temp °C
7 (3—30)
Here you can set the temperature difference determining
when charging to the EHS tank should start. The
EcoTank in system 2 must be this many degrees
warmer than the EHS tank for charging to start.
Charge stop diff temp °C
3 (2—20)
Here you can set the temperature difference determining
when charging to the EHS tank should stop. When the
temperature difference between the EcoTank and the
EHS tank falls below this set value, charging stops.
Charge temperature °C
60 (10—80)
Setting for the maximum permitted temperature in the
EHS tank. Transfer stops once the set temperature has
been reached.
Содержание GSi 16
Страница 6: ...6 CTC GSi 16...
Страница 48: ...48 CTC GSi 16 8 13 Tank schematic diagram A2...
Страница 49: ...49 CTC GSi 16...
Страница 50: ...50 CTC GSi 16 8 14 HP cooling module schematic diagram A5...
Страница 51: ...51 CTC GSi 16...
Страница 52: ...52 CTC GSi 16 8 15 Expansion card accessory schematic diagram A3 a CTC EcoZenith i350 CTC EcoVent i350F...
Страница 53: ...53 CTC GSi 16...
Страница 54: ...54 CTC GSi 16 M GF B25 B26 Y21 B5 G20 B24 B23 B27 B28 G11 G5 B102 B18...
Страница 61: ...61 CTC GSi 16...
Страница 119: ......
Страница 120: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 012 162 205 94 1 06 02 2019...