![CTC Union GSi 16 Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/ctc-union/gsi-16/gsi-16_installation-and-maintenance-manual_2693361042.webp)
42
CTC GSi 16
8.1
Sensor connection
Sensor connection is carried out on top of the main product.
Sensor terminal block
i
Do not attach the
sensor cable perma-
nently until you have
tested and determi-
ned the best loca-
tion.
Connection of outdoor sensor (B15)
The outdoor sensor is connected to G11–G12 on the sensor terminal block.
The sensor should be set up on the house’s northwest or north side, so that
it is not exposed to morning and evening sun. If there is a risk of the sensor
being affected by the sun’s rays, it must be protected by a screen.
Place the sensor at around 2/3 of the height of the facade near a corner, but
not under a roof projection or other form of wind protection. Do not place it
either above ventilation ducts, doors or windows where the sensor may be
affected by factors other than the actual outdoor temperature.
Connection of room sensors (B11 and B12)
Connect room sensor 1 to G17–G19.
Connect room sensor 2 to G20–G22.
The room sensor is fitted at a central point in the house, in the most open
position possible, ideally in a hall between several rooms. This is the best
position for the sensor to record an average temperature for the house.
Feed a three-conductor cable (minimum 0.5 mm
2
) between the heat pump
and room sensor. Then attach the room sensor securely in a position roughly
two thirds of the way up the wall. Connect the cable to the room sensor and
heat pump.
When connecting a wireless room sensor (accessory), refer to the
accessory's manual.
Check room sensor connection
• Go to the menu:
Installer/Service/Function test/Heating system.
• On line
Diode room sensor, press OK.
• Select
On using the + button and press OK.
Check that the room sensor LED lights up. If not, check the cables and
connection.
• Select
Off using the - button and press OK. If the OK LED goes off, the
check is complete.
• Return to start menu by pressing the Home button.
Room sensor 1 (B11)
Sensor terminal
block
Terminal
block, room
sensor
G17
#1 (alarm)
G18
#2
G19
#4
Room sensor 2 (B12)
Sensor terminal
block
Terminal
block, room
sensor
G20
#1 (alarm)
G21
#2
G22
#4
Содержание GSi 16
Страница 6: ...6 CTC GSi 16...
Страница 48: ...48 CTC GSi 16 8 13 Tank schematic diagram A2...
Страница 49: ...49 CTC GSi 16...
Страница 50: ...50 CTC GSi 16 8 14 HP cooling module schematic diagram A5...
Страница 51: ...51 CTC GSi 16...
Страница 52: ...52 CTC GSi 16 8 15 Expansion card accessory schematic diagram A3 a CTC EcoZenith i350 CTC EcoVent i350F...
Страница 53: ...53 CTC GSi 16...
Страница 54: ...54 CTC GSi 16 M GF B25 B26 Y21 B5 G20 B24 B23 B27 B28 G11 G5 B102 B18...
Страница 61: ...61 CTC GSi 16...
Страница 119: ......
Страница 120: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 012 162 205 94 1 06 02 2019...