![CTC Union GSi 16 Скачать руководство пользователя страница 69](http://html1.mh-extra.com/html/ctc-union/gsi-16/gsi-16_installation-and-maintenance-manual_2693361069.webp)
69
CTC GSi 16
CTC GSi 16
Stored oper data
Compressor
Heating circuit
Status DHW
DHW tank °C
49/ 45 (55)
DHW ºC
54 (50) 73%
Degree minute
-1000
Electric power kW
0.0
Current L1/L2/L3
0.0
Diff func. Pump/ ºC
Off 30
Pool ºC
0 (22)
DHW circulation
Off
External heat source
Off 50
12.4.1
Operational data CTC GSi 16
This menu displays current temperatures and operating
data. The first figure is the actual operational value, with
the value in brackets being the setpoint which the heat
pump is trying to achieve.
Status
Shows operating status. The various operating statuses
are:
-> DHW
DHW is produced.
-> HC
Heat is produced for the heating circuit (HC).
-> Pool
Heat is produced for the pool.
-> Off
No heating takes place.
DHW tank °C
49/ 45 (55)
Displays hot water temperatures in the tank: upper part
and lower part. The value in brackets is the setpoint
(stop temp). The setpoint is measured in the upper part
of the tank.
DHW °C
54 (50) 72%
Display of current temperature, current set point and
current energy amount. If no hot water is drawn then no
temperature is shown, just the setpoint.
Degree minute
-1000
Shows current heat loss in degree minutes.
Electric power kW
Shows the output from the immersion heater (0 to 9.0
kW).
Current L1/L2/L3
Shows the system’s total current consumption at
the various phases L1/L2/L3, provided that three
current sensors (accessories) have been fitted to the
unit’s incoming cables. If the current sensors are
not identified, only the phase with the highest load is
displayed. If the current exceeds the main fuse size,
the boiler automatically switches down a power step
to protect the fuses, for example, when several high-
consumption appliances are being used in the house.
i
“Degree minutes” refers to the
product of the cumulative heat
loss in degrees (°C) and the time
measured for this in minutes.
Содержание GSi 16
Страница 6: ...6 CTC GSi 16...
Страница 48: ...48 CTC GSi 16 8 13 Tank schematic diagram A2...
Страница 49: ...49 CTC GSi 16...
Страница 50: ...50 CTC GSi 16 8 14 HP cooling module schematic diagram A5...
Страница 51: ...51 CTC GSi 16...
Страница 52: ...52 CTC GSi 16 8 15 Expansion card accessory schematic diagram A3 a CTC EcoZenith i350 CTC EcoVent i350F...
Страница 53: ...53 CTC GSi 16...
Страница 54: ...54 CTC GSi 16 M GF B25 B26 Y21 B5 G20 B24 B23 B27 B28 G11 G5 B102 B18...
Страница 61: ...61 CTC GSi 16...
Страница 119: ......
Страница 120: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 012 162 205 94 1 06 02 2019...