Cooling
Common Heating and Cooling?
No
Condense Secured
No
Room temp cooling
25.0
Smart low price ºC
1
Smart overcapacity ºC
2
12.10 Cooling
Free cooling is adjusted using primary flow sensor
2 (B2), which then means that heating circuit 2 and
cooling cannot be used simultaneously.
Common Heating and Cooling
No (No/Yes)
Yes means that free cooling and heat are distributed in
the same channels.
Condense pipe secured
No (No/Yes)
If a condense pipe for the system has been secured,
significantly lower temperatures are permitted at
various points in the system. WARNING Build-up of
condensation in the house structure can lead to damp
and damage from mildew.
(No) means a setting range for room temperature of
18–30°C and (Yes) means a setting range of 10–30°C
In the event of doubt, contact an expert surveyor for an
assessment.
Room temp cooling
25.0 (10.0 or 18.0—30.0)
This is used to set the desired room temperature for
cooling.
Smart low price. °C
1 ( Off, 1—5 )
Read more in the “Smartgrid” section.
Smart over capacity °C
1 ( Off, 1—5 )
Read more in the “Smartgrid” section.
Содержание GSi 16
Страница 6: ...6 CTC GSi 16...
Страница 48: ...48 CTC GSi 16 8 13 Tank schematic diagram A2...
Страница 49: ...49 CTC GSi 16...
Страница 50: ...50 CTC GSi 16 8 14 HP cooling module schematic diagram A5...
Страница 51: ...51 CTC GSi 16...
Страница 52: ...52 CTC GSi 16 8 15 Expansion card accessory schematic diagram A3 a CTC EcoZenith i350 CTC EcoVent i350F...
Страница 53: ...53 CTC GSi 16...
Страница 54: ...54 CTC GSi 16 M GF B25 B26 Y21 B5 G20 B24 B23 B27 B28 G11 G5 B102 B18...
Страница 61: ...61 CTC GSi 16...
Страница 119: ......
Страница 120: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 012 162 205 94 1 06 02 2019...