Chapter 4. Web Configuration & Operation
82
CHAPTER 3
WEB OPERATION & CONFIGURATION
Frame error event threshold:
This four-octet field indicates the number of detected errored frames in the period is
required to be equal to or greater than in order for the event to be generated. 1) The default value is one frame error.
2) The lower bound is zero frame errors. 3) The upper bound is unspecified.
Frame errors:
This four-octet field indicates the number of detected errored frames in the period.
Total frame errors:
This eight-octet field indicates the sum of errored frames that have been detected since the OAM
sub-layer was reset.
Total frame error events:
This four-octet field indicates the number of Errored Frame Event TLVs that have been
generated since the OAM sublayer was reset.
Local & Remote Frame Period Status
Frame Period Error Event Timestamp:
This two-octet field indicates the time reference when the event was
generated, in terms of 100 ms intervals.
Frame Period Error Event Window:
This four-octet field indicates the duration of period in terms of frames.
Frame Period Error Event Threshold:
This four-octet field indicates the number of errored frames in the period is
required to be equal to or greater than in order for the event to be generated.
Frame Period Errors:
This four-octet field indicates the number of frame errors in the period.
Total frame period errors:
This eight-octet field indicates the sum of frame errors that have been detected since the
OAM sub-layer was reset.
Total frame period error events:
This four-octet field indicates the number of Errored Frame Period Event TLVs that
have been generated since the OAM sub-layer was reset.
Local & Remote Symbol Period Status
Symbol Period Error Event Timestamp:
This two-octet field indicates the time reference when the event was
generated, in terms of 100 ms intervals.
Symbol Period Error Event Window:
This eight-octet field indicates the number of symbols in the period.
Symbol Period Error Event Threshold:
This eight-octet field indicates the number of errored symbols in the period is
required to be equal to or greater than in order for the event to be generated.
Symbol Period Errors:
This eight-octet field indicates the number of symbol errors in the period.
Symbol frame period errors:
This eight-octet field indicates the sum of symbol errors since the OAM sub-layer was
reset.
Symbol frame period error events:
This four-octet field indicates the number of Errored Symbol Period Event TLVs
that have been generated since the OAM sub-layer was reset.
Local & Remote Event Seconds Summary Status
Event Seconds Summary Time Stamp:
This two-octet field indicates the time reference when the event was
generated, in terms of 100 ms intervals, encoded as a 16-bit unsigned integer.
Event Seconds Summary Window:
This two-octet field indicates the duration of the period in terms of 100 ms
intervals, encoded as a 16-bit unsigned integer.