GH DRIVER
9-
8
Function
code
Name
Description
Setting
scope
Unit
Factory
setting
Change
Recommend
motor
C1.05
Pulse speed order
source
2: T4
3: T2
4: T3
Other : Invalid
0~5
-
0
×
Synchronous/
Asynchronous
C1.06
Positioning
maximum speed
Positioning execute process maximum limit
speed
0~30000
rpm
100
○
Synchronous/
Asynchronous
C1.07
Positioning
acceleration time
Positioning process acceleration time of T type
speed
0~300.00
0.01s
0.50
○
Synchronous/
Asynchronous
C1.08
Positioning
direction
0: Forward 1: Reverse
0
,
1
-
0
○
Synchronous/
Asynchronous
C1.09
First positioning gain First gain during positioning, the gain is greater
0~60000
-
300
○
Synchronous/
Asynchronous
C1.10
Second positioning
gain
Second gain during positioning , the gain is
smaller
0~60000
-
50
○
Synchronous/
Asynchronous
C1.11
Positioning gain
switch point
Positioning first gain and second gain switch
threshold , when the residue distance is
smaller than the value, switch to second gain ,
otherwise, use first gain
0~600.00
0.01R
0.10
○
Synchronous/
Asynchronous
C1.12
Positioning
minimum speed
Positioning process minimum speed
0~600.00 0.01rpm
0.01
○
Synchronous/
Asynchronous
C1.13
Third section
positioning switch
point
Third section positioning distance threshold ,
when the residue distance is smaller than the
parameter, conduct third section positioning
operation
0~300.00
0.01R
0
○
Synchronous/
Asynchronous
C1.14
Coarse positioning
scope
When positioning residue distance is smaller than
the value, it is determined that the positioning is
reached, and output positioning reach signal
0~6.0000
Pulse
0.01
○
Synchronous/
Asynchronous
C1.15
Save
-
-
-
-
-
-
C1.16
Precise positioning
scope
When positioning residue distance is smaller
than the value, it is determined that the precise
positioning is reached, and output precise
positioning reach signal
0~3.0000
Pulse
0.01
○
Synchronous/
Asynchronous
C1.17
Swing forward
scope
Swing forward position
0~30000
Pulse
300
○
Synchronous/
Asynchronous
C1.18
Swing reverse scope Swing reverse position
0~30000
Pulse
300
○
Synchronous/
Asynchronous
C1.19
Swing speed upper
limit
Maximum speed during swing
0~600.0
rpm
100.0
○
Synchronous/
Asynchronous
C1.20
Swing acceleration Acceleration during swing
0~300.00
s/krpm
1.00
○
Synchronous/
Asynchronous
C1.21
Swing deceleration Deceleration during swing
0~300.00
s/krpm
1.00
○
Synchronous/
Asynchronous
C1.22
Swing current
Swing current
0~300.00
A
3.0
○
Synchronous/
Asynchronous
C1.23
Save
-
-
-
-
-
-
C1.24
C1.25
Positioning maximum
deceleration
Take the deceleration as lower limit of
deceleration after entering positioning module
0~200.00
-
0
○
Synchronous/
Asynchronous