GH DRIVER
5-
18
Function
code
Name
Description
Setting
scope
Unit
Factory
setting
Change
Recommend
motor
Cn.00
Motor running
direction
0: anticlockwise is forwardrunning
1: clockwise is forward running
0,1
-
0
X
Synchronous/
Asynchronous
Cn.01
acceleration time
speed modeacceleration time
0~200.00
s
0.8
○
Synchronous/
Asynchronous
Cn.02
deceleration time
speed modedeceleration time
0~200.00
s
0.8
○
Synchronous/
Asynchronous
Cn.03
Acceleration start
S-curve time
Acceleration start S-curve time setting
0~200.00
s
0
○
Synchronous/
Asynchronous
Cn.04
Acceleration close
S-curve time
Acceleration close S-curve time setting
0~200.00
s
0
○
Synchronous/
Asynchronous
Cn.05
Deceleration start
S-curve time
Deceleration start S-curve time setting
0~200.00
s
0
○
Synchronous/
Asynchronous
Cn.06
Deceleration close
S-curve time
Deceleration close S-curve time setting
0~200.00
s
0
○
Synchronous/
Asynchronous
Cn.07
Emergency
deceleration time
Emergency deceleration time for external
emergency stop input
0~200.00
s
0.8
○
Synchronous/
Asynchronous
Cn.08
Enable close delay
time
After slowing down and stopping, the module
will be closed in time to prevent rotation
0~200.00
s
0.4
○
Synchronous/
Asynchronous
Cn.09
parking pattern
selection
0:Slow down and stop
1:Free stop
0,1
-
1
○
Synchronous/
Asynchronous
Cn.10
Load current limit
Output max torque current=Cn.10×Dn.01/100
0~1000
%
150
○
Synchronous/
Asynchronous
Cn.11
Energy consumption
brake current limit
0: not enabled
Brake output maximum torque current
= Cn. 11 x Dn. 01/100
0~1000
%
0
○
Synchronous/
Asynchronous
Cn.12
DC braking starting
speed
When the parking mode is deceleration parking,
the dc braking is triggered when the current
speed is less than cn.12, and the dc braking is
not started when cn.12 is 0
0~60000
rpm
0
○
Synchronous/
Asynchronous
Cn.13
DC brake current
limitation
Maximum output current of DC braking
= Cn. 13 x Dn. 01/100
0~1000
%
50
○
Synchronous/
Asynchronous
Cn.14
DC braking delay time DC braking holding time after motor zero speed
0~200.00
s
0
○
Synchronous/
Asynchronous
Cn.15
Motor control
parameters matching
Automatic matching of motor control
parameters
1
-
0
X
Synchronous/
Asynchronous
Cn.16
Motor 1 current loop
proportional parameter
current loop proportional parameter Kp setting
0~30000
-
100
○
Synchronous/
Asynchronous
Cn.17
Motor 1 current loop
integral time constant
Current loop integral time constant Ti setting
0~300.00
-
4
○
Synchronous/
Asynchronous
Cn.18
Motor 1 current loop
decoupling function
0: turn off decoupling function of current loop
1: turn on decoupling function of current loop
0, 1
-
0
X
Synchronous/
Asynchronous
Cn.19
Motor 1 speed loop
proportional gain
Speed loop proportional gain Kp setting
0~65535
-
300
○
Synchronous/
Asynchronous
Cn.20
Motor 1 speed ring
integral time constant
Speed ring integral time constant Ti setting
0~65535
-
40
○
Synchronous/
Asynchronous
User parameters Cn