GH DRIVER
9-
4
Function
code
Name
Description
Setting
scope
Unit
Factory
setting
Change
Recommend
motor
A2.02
Save
-
-
-
-
-
Synchronous/
Asynchronous
A2.03
Positioning mode
0: Motor encoder positioning
1: Spindle encoder positioning
2: Approach switch positioning
0~2
-
0
×
Synchronous/
Asynchronous
A2.04
Save
-
-
-
-
Synchronous/
Asynchronous
A2.05
Selection of Pulse
Location Chain
Mode
0: Direct access to pulse position mode when
I4 is switched on
1: When I4 is switched on, the quasi-stop is
executed first, and then the quasi-stop is
completed before entering the pulse
position mode and outputting the pulse
position interlocking completion signal.
0、1
-
0
×
Synchronous/
Asynchronous
A2.06
Save
-
-
-
-
-
-
~
A2.10
A2.11
Selection of ST
deceleration
mode
0: Slow down and stop when ST terminal is
revoked
1: Free parking when removing ST terminals
0、1
-
0
×
Synchronous/
Asynchronous
A2.12
ST function
selection
0: ST terminal invalid
1: ST as MODBUS communication enabled
terminal
0、1
-
0
×
Synchronous/
Asynchronous
A2.13
Positioning mode
0: Positioning according to current speed
direction
1: Positioning according to A2.14 parameter set
direction
0、1
-
0
×
Synchronous/
Asynchronous
A2.14
Positioning
direction selection
0: Positive positioning
1: Negative positioning
0、1
-
0
×
Synchronous/
Asynchronous
A2.15
I1 function
selection
0: Analog quantity speed
1: Pulse speed
0、1
-
0
×
Synchronous/
Asynchronous
A2.16
Single and Double
Pulse Selection for
T2, T3 and T4 Pulse
Input (Bit Settings)
Whether Bit0 Pulse Input Type SettingFunction
is Open
0: Close, 1: open
T4 Type of Bit1 Pulse Input Port
0: pules+directiong, 1: Orthogonal Pulse
Bit2 pulse input T3
0: pulse+direction, 1: Orthogonal Pulse
Bit3pulse input T2
0: pulse+direction, 1: Orthogonal Pulse
0~15
-
15
×
Synchronous/
Asynchronous
A2.17
Pulse port selection
0: T4 port( pulse type set by E1.15)
1: T2 port( pulse type set by E1.21)
2: T3 port(pulse type set by E1.27)
0~2
-
0
×
Synchronous/
Asynchronous