GH DRIVER
5-
2
Parameter list description
The contents of the parameter list are described as follows:
Function code: Code of parameter group and parameter number;
Name: Name of the parameter;
Description: Detailed description about function and effective setting value of the parameter;
Setting range: The range of effective setting value of parameter;
Unit: Parameter setting unit;
Factory setting: Original factory parameter setting;
Change: Parameter changing properties (ie, allow changing or not and change condition) are as follows:
“O” the parameter setting can change when the driver is in downtime and in running state.
“×” the parameter setting can’t change when the driver is in servo enabled state.
“*” the parameter value is actual test record value, it can’t change.
“
Δ
” the revised parameter setting need to electricity to effect
Apply motor Apply motor type as follow:
Synchronous: the parameter is applicable to the synchronous motor only.
Asynchronous: the parameter is applicable to the asynchronous motor only.
Synchronous/Asynchronous: the parameter is applicable to the synchronous and asynchronous motor.
Running monitoring parameter U1
Running monitoring parameter U2
Function
code
Name
Description
Unit
Change
Apply motor
U1.00
Set speed/frequency
Max speed<1000rpm, display speed;
Max speed≥1000rpm, display frequency
Speed: rpm
Frequency:Hz
*
Synchronous/
Asynchronous
U1.01
Output speed/frequency
Synchronous/
Asynchronous
U1.02
Feedback speed/frequency
Synchronous/
Asynchronous
U1.03
Driver output current
Monitor drive output current
A
*
Synchronous/
Asynchronous
U1.04
Drive output voltage
Monitor drive output voltage
V
*
Synchronous/
Asynchronous
U1.05
Driver DC bus voltage
Monitor DC bus voltage=AC power line voltage*1.414
V
*
Synchronous/
Asynchronous
U1.06
Motor actual feedback torque
Monitor motor output torque, display as per the motor
rated torque percentage
%
*
Synchronous/
Asynchronous
Function
code
Name
Description
Unit
Change
Apply
motor
U2.00
Motor encoder counting value
Monitor motor encoder counting value
Pulse
*
Synchronous/
Asynchronous
U2.01
Second encoder counting value
When Encoder input,
4 frequency multiplication counting
When single pulse input,
1 frequency multiplication counting
When double pulse input,
4 frequency multiplication counting
Pulse
*
Synchronous/
Asynchronous
U2.02
Following error
Following error
Pulse
*
Synchronous/
Asynchronous
U2.03
State of input points I1 to I6, ST,
RST
-
*
Synchronous/
Asynchronous
U2.04
State of input points I7 to I12
U2.05
state of output M0, M1, Q0 to Q6
-
*
Synchronous/
Asynchronous
Valid
Invalid
I6 I5 I4 I3 I2 I1 RST ST
I12 I11 I10 I9 I8 I7
M1 M0 Q6 Q5 Q4 Q3 Q2 Q1