GH DRIVER
5-
33
Function
code
Name
Description
Setting
scope
Unit
Factory
setting
Change
Recommend
motor
Fn.47
PID given
acceleration and
deceleration time
PID to the quantitative acceleration and
deceleration time, can alleviate the impact
caused by too fast change
0~50.00
s
0
○
Synchronous/
Asynchronous
Fn.48
PID feedback filter
coefficient
PID feedback low-pass filter, 0 means no
filtering, the larger the value, the more obvious
the filtering effect, the more obvious the lag
0~512
-
0
○
Synchronous/
Asynchronous
Fn.49
PID output filter
coefficient
PID output low-pass filter, 0 means no filtering,
the larger the value, the more obvious the
filtering effect, the more obvious the lag
0~512
-
0
○
Synchronous/
Asynchronous
Fn.50
PID Register output
internal register
When PID selects memory register output, the
output register address
-100.0~
100.0
-
0
○
同/异
Fn.51
PID Feedback loss
detection window
time
Time setting of PID feedback loss detection
window
0~50.00
-
0
○
同/异
Fn.52
PID given display
Based on the given percentage X fn.33
0~65535
-
0
*
Synchronous/
Asynchronous
Fn.53
PID feedback
display
Based on the percentage of feedback X fn.33
0~65535
-
0
*
Synchronous/
Asynchronous
Fn.54
PID integral term
reset
0: invalid
1: reset
0~1
-
0
○
Synchronous/
Asynchronous
Fn.55
External DI05
positioning count
This parameter represents the number of times
a DI05 signal is triggered when external DI05 is
used as a reference source for positioning
0~65535
-
0
*
Synchronous/
Asynchronous
Fn.56
External DI05
positioning latch
position L
When external DI05 is used as the positioning
reference source, the data of position latch
when DI05 is triggered
0~
4294967295
pulse
0
*
Synchronous/
Asynchronous
Fn.57
External DI05
positioning latch
position H
Fn.58
External di05
interrupt polarity
External di05 interrupt polarity:
0: Rising edge
1: Falling edge
0,1
-
0
○
同/异
Fn.59
Save
-
-
-
-
-
-
Fn.60
Forward speed limit
in torque mode
Upper limit of forward speed in torque mode
0~60000
rpm
0
○
Synchronous/
Asynchronous
Fn.61
Negative speed
limit in torque mode
Negative speed upper limit in torque mode
0~60000
rpm
0
○
Synchronous/
Asynchronous
Fn.62
Torque command
acceleration time
In torque mode, the target torque acceleration
time is the time from 0% to 100% of the rated
torque
0~30.00
S
1
○
Synchronous/
Asynchronous
Fn.63
Torque command
deceleration time
In torque mode, the target torque deceleration
time is the time from 100% deceleration to 0%
rated torque
0~30.00
S
1
○
Synchronous/
Asynchronous
Fn.64
Target torque value
Set the target torque of motor and percentage
of rated torque
-500.0
~500.0
%
0
○
Synchronous/
Asynchronous