Crystal Vision
Using card edge controls
TANDEM-300 User Manual R1.2
50
14/02/2008
The EDH menu is obtained with MENU DIL, lever 5 ON (DOWN), all other levers UP
(OFF
)
and the SEL switch in position C for side 1 and D for side 2. Turn the shaft
encoder to select between ‘EDH on’ and ‘EDHoff’.
SEL
Display
Comments
C
SD1 EDH on or EDHoff
Use shaft encoder to select ‘EDH on’ or
‘EDHoff’. It is recommended to leave this
setting as ‘EDH on’ for normal operation.
D
SD2 EDH on or EDHoff
Viewing ancillary data status
An ancillary data monitoring facility has been provided to show the following:
•
SDI status
•
Input audio group present
•
Deletion status
•
EDH data present
The ancillary data status display is obtained with MENU DIL, lever 6 ON (DOWN), all
other levers UP (OFF
)
and the SEL switch in position E for side 1 and F for side 2.
SEL
Display
Comments
E
SD1 1234dE
See notes and examples for detailed explanation
F
SD2 1234dE
Note:
If no SDI input is present on that side the display will read, ‘no inp’.
‘d’ indicates the presence of embedded audio marked for deletion.
‘E’ indicates the presence of EDH inserts.
‘-’ indicates that a possible input (group, deletion flag or EDH insert) is not present.
Examples:
SDI 1----E Audio Group 1 and EDH only present.
SDI -23-d- Audio Groups 2, 3 and ‘Marked for Deletion’ present.
Tip:
A much wider range of Demux and Mux status reporting, including HANC status, is
discussed in Chapter 6, Problem solving.