Power Converters
A power converter is needed where the only supply is AC voltages.
Cranesmart™ power converters change 110/220V
AC to 12/24VDC depending on the application. If a power converter is needed it is normally discussed at the time of
purchase.
Hazardous Location Rated systems
In Class 1 Division 2 or Zone 2 (C1D2 / C1Z2) applications the
Cranesmart™ System panel will wire identically to basic
wiring instruction. The significant difference is that the panel has a pigtail with a Hazardous Location Certified connector
on the end. The connector will mate with the corresponding Hazardous Location Certified Connector on a power cable
or on the cable coming from the alarm hub. When dealing with these connectors utilize hand tools to secure the
connection tight enough so tools will be needed to disconnect them.
Junction Box
The Junction Box is used to connect Power and ground to the panel and BDT - Boom Direction Transducer (see page
38). It also is a pathway of communication between both components. The Junction box comes with the following
cables
5-pin Standard power cable
5-pin Serial cable, to connect the junction box to the panel.
Installation the Junction box
1. Locate a position to mount the Junction Box where the operator can reach the wiring if necessary
2. Align Mark and drill holes using the mounting holes on the box as a guide.
3. Bolt Junction box in place.
4. Wiring in power cord. See section on Electrical Wiring of a
Cranesmart™ Panel
5. Connect Serial cable form Junction box to Panel.
NOTE:
The limiting factor on where you can mount the junction box is based on the lengths of cable you have and were the panel is mounted.
Each Plug is keyed to ensure proper connection.
Содержание LMI System
Страница 1: ...Cranesmart Systems LMI System User Manual May 11 2015 Rev 9...
Страница 23: ...22 Cranesmart LMI Version R9...
Страница 43: ...42 Cranesmart LMI Version R9 Basic Wiring Diagram...
Страница 45: ...44 Cranesmart LMI Version R9 Junction Box Wiring Diagram...
Страница 47: ...46 Cranesmart LMI Version R9 Alarm Hub Wiring Diagram...
Страница 91: ...90 Cranesmart LMI Version R9 Technical Specifications 7 500lb single line pull load cell...
Страница 92: ...91 Cranesmart LMI Version R9 15 000 single line pull load cell...
Страница 93: ...92 Cranesmart LMI Version R9 25 000lb single line pull load cell...
Страница 94: ...93 Cranesmart LMI Version R9 40 000lb single line pull load cell...
Страница 95: ...94 Cranesmart LMI Version R9 50 000lb single line pull load cell...
Страница 96: ...95 Cranesmart LMI Version R9 80 000lb single line pull load cell...
Страница 97: ...96 Cranesmart LMI Version R9 Anti 2 Block Switch...
Страница 98: ...97 Cranesmart LMI Version R9 Boom Angle Transducer...
Страница 99: ...98 Cranesmart LMI Version R9 Display Panel...
Страница 100: ...99 Cranesmart LMI Version R9 Alarm Hub...
Страница 101: ...100 Cranesmart LMI Version R9 Wind Speed Transducer...