18
Cranesmart LMI Version R9
Locate the four exposed hex bolts on the battery compartment side of the Load Cell. If the holes are filled with silicone
you are on the transmitter side of the Load Cell. Do not open this side, it has no user serviceable parts. Your warranty
will be
Void
if the Transmitter Electronics section has been opened.
1. Remove the load cell from the crane.
2. Use the Allen key to remove the four hex bolts.
3. Remove battery from clip (ensure you do not break the red polarisation tab).
4.
Install the new Battery, (positive „+‟ to red polarisation tab).
5. Remove the old o-ring from the aluminum plate and discard.
6. Grease the proper replacement o-ring with your fingers using a portion of the silicone grease supplied with the kit.
7. Install the new greased o-ring into the groove on the aluminum plate. Apply the remaining grease liberally covering the o-ring and groove.
As mentioned above,
Do Not use the RTV silicone sealant
it is for the older gasket style load cell.
8. Place the plastic cover over the Battery pack taking care not to pinch the battery wires.
9. Replace the screws and fully tighten the hex bolts. Some grease may squeeze out depending on the amount grease applied.
10. Clean off any excess grease.
11. Re-install the load cell to test its operation.
Do not use a power drill or power screwdriver to remove or tighten the bolts, you may damage the threads on
the aluminum plate.
Содержание LMI System
Страница 1: ...Cranesmart Systems LMI System User Manual May 11 2015 Rev 9...
Страница 23: ...22 Cranesmart LMI Version R9...
Страница 43: ...42 Cranesmart LMI Version R9 Basic Wiring Diagram...
Страница 45: ...44 Cranesmart LMI Version R9 Junction Box Wiring Diagram...
Страница 47: ...46 Cranesmart LMI Version R9 Alarm Hub Wiring Diagram...
Страница 91: ...90 Cranesmart LMI Version R9 Technical Specifications 7 500lb single line pull load cell...
Страница 92: ...91 Cranesmart LMI Version R9 15 000 single line pull load cell...
Страница 93: ...92 Cranesmart LMI Version R9 25 000lb single line pull load cell...
Страница 94: ...93 Cranesmart LMI Version R9 40 000lb single line pull load cell...
Страница 95: ...94 Cranesmart LMI Version R9 50 000lb single line pull load cell...
Страница 96: ...95 Cranesmart LMI Version R9 80 000lb single line pull load cell...
Страница 97: ...96 Cranesmart LMI Version R9 Anti 2 Block Switch...
Страница 98: ...97 Cranesmart LMI Version R9 Boom Angle Transducer...
Страница 99: ...98 Cranesmart LMI Version R9 Display Panel...
Страница 100: ...99 Cranesmart LMI Version R9 Alarm Hub...
Страница 101: ...100 Cranesmart LMI Version R9 Wind Speed Transducer...