21
•
European Rules. If enabled, the VCU will
set the clock back one hour on the last
Sunday of October (1:00 AM), set the clock
ahead one hour on the last Sunday in
March (1:00 AM).
•
Australian Rules. If enabled, the VCU will
set the clock back one hour on the last
Sunday of March (1:00 AM), set the clock
ahead one hour on the first Sunday in
October (1:00 AM).
Press the “CLR” key to return to “Daylight Savings
Time”. Press the “CLR” key to return to “TEST
MODE” or press the “A” key to advance to the next
menu item below.
NOT AVAILABLE MODE
-
Press key “3”
This setting works in conjunction with the “SET NOT
AVAILABLE TIME” (option 3 in Setup Mode 1). This
setting must be showing “Not Available # On” in
order for the Not Available times to function as
programmed. This mode can also be used to
manually disable the times established in ‘NOT
AVAILABLE TIME” mode as long as the function is
set to “Not Available # Off”. Press the number “3” on
the keypad and the display will show “NOT
AVAILABLE MODE”. Press the
Key and display
will show “Select Block (1 – 4). Press the select
block group you wish to enter. Display will show
“Not Available #: On (Off) Press
turn off (on) to
change the status. Factory default for this setting is
Off. Pressing the “
” key will toggle the state and
set the controller to the new condition shown on the
display (pushing the “
” key with ON on the display
will ALLOW the not available mode to function as
programmed). Press the “CLR” key to return to “Not
Available Mode”. Press the “CLR” key to return to
“TEST MODE” or press the “A” key to advance to
the next menu item below.
CREDIT TIMER MODE
-
Press key “4”
Allows the service technician to set the vender to
cancel a credit or keep a credit showing on the
display after 5 minutes. Press the number “4” on the
keypad and the display will show “CREDIT TIMER
MODE”. Press the “
” Key and the display will
show “Credit Timer: Off (On) Press “
” - turn On
(Off). “Credit Timer Off” will save a credit
indefinitely.
“Credit Timer On” will only save a credit
for five minutes. Press the “CLR” key to return to
“Credit Timer Mode”. Press the “CLR” key to return
to “TEST MODE” or press the “A” key to advance to
the next menu item below.
DOOR OPEN
-
Press key “5”
Shows number of times the service door has been
opened since last “CLEAR TOTALS” or “MASTER
RESET”. Press the number “5” on the keypad and
“DOOR OPEN” will show on the display. Press the
“
” Key and “Door Opened # Times ##:## ## Month
YEAR” will show on display. This is the number of
times the service door has been opened since the
last “CLEAR TOTALS” or “MASTER RESET” and
the time, day, and date of the last opening. Press
Key “A” to see the time of the 5 previous openings.
Press the “CLR” key to return to “Door Open”. Press
the “CLR” key to return to “TEST MODE” or press
the “A” key to advance to the next menu item below.
POWER OUT
-
Press key “6”
Shows the number of times the machine has lost
power since last “CLEAR TOTALS” or “MASTER
RESET”. (This is a power outage for any reason
including the machine being unplugged or the
machine’s master power switch being turned off).
Press the number “6” on the keypad and “POWER
OUT” will show on the display, press the “
” Key
and “Power Lost # Times will show on the display
and the date and time of the last outage which is the
number of times power has been lost to the control
board since the last “CLEAR TOTALS” or “MASTER
RESET”. Press Key “A” to see the time of the 5
previous outages Press the “CLR” key to return to
“Power Out”. Press the “CLR” key to return to
“TEST MODE” or press the “A” key to advance to
the next menu item below.
TEST HEALTH GUARD
-
Press key “7”
This setting is in place to test the functioning of the
health guard system by simulating a Health Code
Error. Once activated, any selections programmed
in “HEALTH CONTROL MODE” in the Setup Mode 1
will be disabled. To test health guard, press the
number 7 on the keypad and the display will show
“TEST HEALTH GUARD”. Push the “
” key and the
display will change to “Test Health Guard?
= Y
CLR = N. Press “
” and display will show Health
Guard” then change to “Activated”. The display will
then return to “TEST HEALTH GUARD”. Within one
minute of returning the vender to service, items that
were turned on in “HEALTH CONTROL MODE”
setting in SETUP MODE 1 will be put out of service.
Additionally, a “HEALTH” error will be displayed in
‘LIST ERRORS”. Errors must be cleared before
programmed items can be returned to service.
Press the “CLR” key to return to “Test Health
Guard”. Press the “CLR” key to return to “TEST
MODE” or press the “A” key to advance to the next
menu item below.
DISPLAY HEALTH GUARD
-
Press key “8”
Allows the service technician to view the selections
that are listed under the “HEALTH CONTROL
MODE” in the SETUP MODE 1. Press the number
“8” on the keypad and the display will read
“DISPLAY HEALTH GUARD”. Press the “
” key
and the selection(s) that are listed under the health
control will be displayed or “NONE ASSIGNED” if no
selections are listed. Press the “
” key to continue.
Содержание BevMax 4
Страница 2: ...1 ...
Страница 69: ...68 ...
Страница 70: ...69 MACHINE FRONT VIEW 6A 9 11 13 14 5B 5A 7 3A 4B 19 18 6B 3C 4B 4A 2 4C 17 16 1 12 20 ...
Страница 72: ...71 CABINET DETAIL PRODUCT AREA 3 2B 12 9 6 7 2A 8 5 14 11 ...
Страница 74: ...73 CABINET DETAIL SERVICE DOOR AREA 1 16 10 4 7 11 5 17 11 4 5 20 22 21 14 12 2 10 15 8 ...
Страница 78: ...77 DELIVERY PICKER CUP ASSEMBLY 11 1 2 21 10 5 16 14 15 17 4 7 12 13 19 6 19 20 9 8 19 3 22 ...
Страница 80: ...79 SERVICE DOOR OUTSIDE 3 1 4 12 18 20 25 5 7 8B 8B 23 9 15 14 18 17 8A 21 16 13 26 19D 19B 6 10 24 27 ...
Страница 82: ...81 SERVICE DOOR INSIDE 1 5 10 3 11 25 6 2 25 35 9 15 14 10 17 34 19 23 24 20 9 4 5 18 21 22 8B 26 29 7 8A ...
Страница 84: ...83 GATE TRAY DETAIL 8 3 7 11 1 2 4 6 12 13 14 10 9 ...
Страница 92: ...91 REFRIGERATION UNIT BevMax 4 with Metal Evap Box prior to 9539 0032DJ 26 2 10 18 13 11 15 28A 28C 6 16 9 27 ...
Страница 94: ...93 ELECTRONICS Pepsi Generic BevMax 4 EXE Control Boards 3 1 7 5 4 6 7 Executive 4 pin interface added ...
Страница 96: ...95 HARNESSES 8 2 10 1 4 9 3 6 7 11 24 18 17 12 21 16 23 19 20 15 25 26 22 5 ...
Страница 98: ...97 ...