40
Check, repair, or replace switch
or harness. Problem solved?
YES
NO
Replace
control board.
Check All Home
LED’s are on.
Does motor run?
YES
NO
Check, repair, replace
harness. Problem solved?
YES
NO
Replace
control board.
Check belt
and pulley.
Is the Green
LED on?
YES
NO
Do a Vend
Test with
Door Closed.
Is the display showing Encoder count with
a “1” at the end of the Y Axis code?
YES
NO
###### 1 ###### 1
X axis Y axis
“1” showing = a switch or
ground wire issue.
“0” showing = a
mechanical
obstruction.
NO
YES
Check & replace motor.
Problem solved?
YES
NO
Y Axis Home =
Green light
ON
OFF
Manually move cup to A9 and
pull top door switch out.
Press the “F” key. Picker Cup goes
to the home position?
YES
NO
Manually activate the switch
and light cycles on and off.
YES
NO
Содержание BevMax 4
Страница 2: ...1 ...
Страница 69: ...68 ...
Страница 70: ...69 MACHINE FRONT VIEW 6A 9 11 13 14 5B 5A 7 3A 4B 19 18 6B 3C 4B 4A 2 4C 17 16 1 12 20 ...
Страница 72: ...71 CABINET DETAIL PRODUCT AREA 3 2B 12 9 6 7 2A 8 5 14 11 ...
Страница 74: ...73 CABINET DETAIL SERVICE DOOR AREA 1 16 10 4 7 11 5 17 11 4 5 20 22 21 14 12 2 10 15 8 ...
Страница 78: ...77 DELIVERY PICKER CUP ASSEMBLY 11 1 2 21 10 5 16 14 15 17 4 7 12 13 19 6 19 20 9 8 19 3 22 ...
Страница 80: ...79 SERVICE DOOR OUTSIDE 3 1 4 12 18 20 25 5 7 8B 8B 23 9 15 14 18 17 8A 21 16 13 26 19D 19B 6 10 24 27 ...
Страница 82: ...81 SERVICE DOOR INSIDE 1 5 10 3 11 25 6 2 25 35 9 15 14 10 17 34 19 23 24 20 9 4 5 18 21 22 8B 26 29 7 8A ...
Страница 84: ...83 GATE TRAY DETAIL 8 3 7 11 1 2 4 6 12 13 14 10 9 ...
Страница 92: ...91 REFRIGERATION UNIT BevMax 4 with Metal Evap Box prior to 9539 0032DJ 26 2 10 18 13 11 15 28A 28C 6 16 9 27 ...
Страница 94: ...93 ELECTRONICS Pepsi Generic BevMax 4 EXE Control Boards 3 1 7 5 4 6 7 Executive 4 pin interface added ...
Страница 96: ...95 HARNESSES 8 2 10 1 4 9 3 6 7 11 24 18 17 12 21 16 23 19 20 15 25 26 22 5 ...
Страница 98: ...97 ...