21
POOLDENS
COSMOGAS
C
B
A
020010.01.011
D
020010.01.012
Figure 5-1 - Undoing transport pallet screws
5.1 - Selection of place of installation
WARNING! Do not store any inflammable
material in the appliance’s immediate vicinity.
WARNING! Do not install the appliance on
carpet.
WARNING! The appliance must be installed in
a room in which there is a supply of air for ventilation
and combustion, regardless of whether it is taken
from outside (sealed combustion) or from inside
(combustion in ventilated room).
WARNING! Inadequate ventilation of the
appliance can cause elevated air temperatures.
WARNING! Make sure that the intake and outlet
openings are the right size and that there are no
obstructions and blockages. If the problem cannot be
resolved, do not start up the appliance. Please keep in
mind these restrictions and the risks they may cause to
the operator.
WARNING! Liquified Petroleum Gas (LPG) - The
installation needs particular attention: LPG appliances
must not be installed in trenches, cellars or similar
rooms in which the gas, which is heavier than air, could
hang. LPG powered appliances must not be installed in
places below floor level or basements. If these remarks
are not respected, explosions could result and cause
serious injury to people, death or enormous material
damage.
5 - INSTALLATION - Place of installation
WARNING! If installed in rooms with a thin floor,
a resonating noise could be generated. The installation
of noise-reduction elements is required.
WARNING! The appliance must only be installed
on a solid floor, which takes its weight and is level.
Before installation, carefully wash out the system to remove
any possible residues or impurities that might compromise
operation of the appliance itself.
This appliance is not designed to be installed in the open
air, it must not be exposed to temperatures below 0.5°C
and above 50°C. Choose a place inside the building or at
any rate sheltered from weather such as rain, wind, sun
and, above all, frost.
This appliance must be installed in a place where any
leakage of water that comes from it, from the joints
between pipes or from any discharge from the safety
valve, cannot cause any damage to materials or things
below it.
Determine the room and the right position for installation,
taking the following factors into account:
- connection to smoke outlet/air intake ducts;
- connection to gas adduction duct;
- connection to water supply;
- connection to system to be served (swimming pool and/or
jacuzzi);
- electrical connection;
- connection to outlet for condensate produced;
- electrical connection to high precision control thermostat;
- connection to safety valve outlet;
- room ventilation.
Содержание POOLDENS 100T
Страница 2: ......
Страница 79: ...79 POOLDENS COSMOGAS 16 MAINTENANCE Figure 16 14 Multi wire wiring diagram part 2 continued from previous page ...
Страница 82: ...82 POOLDENS COSMOGAS 16 MAINTENANCE Figure 16 15 Multi wire wiring diagram part 3 continued from previous page ...
Страница 95: ......
Страница 96: ...COSMOGAS s r l Via L da Vinci 16 47014 MELDOLA FC ITALY info cosmogas com www cosmogas com ...