![COSMOGAS MYDENS 60 Скачать руководство пользователя страница 47](http://html.mh-extra.com/html/cosmogas/mydens-60/mydens-60_installation-use-and-maintenance-manual_2670681047.webp)
47
MYDENS 60
COSMOGAS
7 - USE
7.19 - Diagnostics
During normal appliance operation, the visual display “N”
in figure 7.1, continuously shows the working status of the
appliance via the following indications:
Parameter
Description of the parameter
Display on visual display “N” in figure 7.1
AFro
Anti-freeze function active
Appliance temperature (°C)
AttE
Boiler not in block but in attention mode
Attention code (see chapter 7.19.3 for decoding)
FILL
Plant pressure too low, perform loading (see chapter 6.1.3)
FILL
Fixed on = Domestic hot water service on but not active
On flashing = Domestic hot water service on and active
Domestic hot water temperature (°C)
Fixed on = Central heating service on but not active
On flashing = Central heating service on and active
Central heating temperature (°C)
Loc
Boiler blocked. To reset, press
RESET
. If the block occurs
frequently, contact a professionally qualified technician
Block code (see chapter 7.19.1 for decode)
Err
Boiler in error mode. Functioning can only be restored by
solving the cause of the anomaly. Contact a professionally
qualified technician
Error code (see chapter 7.19.2 for decode)
ALEg
Anti-legionella function running (see chapter 5.15.1).
It will end on reaching the water temperature of 60°C inside the
Indirect Water Heater.
Indirect Water Heater temperature (°C)
SEr
Maintenance request for the boiler
Appliance temperature (°C)
Содержание MYDENS 60
Страница 63: ...63 MYDENS 60 COSMOGAS 8 MAINTENANCE ...
Страница 71: ......
Страница 72: ...COSMOGAS s r l Via L da Vinci 16 47014 MELDOLA FC ITALY info cosmogas com www cosmogas com ...