Applications manual
For AME series
6.2.7
READ_REMOTE_CH_PRM [1Eh] [09h] [1Eh] [09h]
The relationship between the argument (binary) and target slots is shown below.
Return value : 0
=>
OFF or blank
Return value : 1
=>
ON
Return value : 01010b
=>
slot1, slot3 ON
Return value : 11011b
=>
slot1, slot2, slot3 ON
*If slot2 is blank.
Return value : 11111b
=>
slot1, slot2, slot3, slot4 ON
6.2.8
READ_REMOTE_PRM [1Eh] [09h] [1Eh] [08h]
Return value:0
=>
OFF
Return value:1
=>
ON
If the input module is target, an error is returned.
(Error code 6 : Command that do not correspond to the setting target)
6.2.9
READ_REMOTE_CONTROL [1Eh] [09h] [1Eh] [01h]
This command returns the output status information (enabled/inhibited).
Return value:0
=>
OFF
Return value:1
=>
ON
If the input module is target, an error is returned.
(Error code 6 : Command that do not correspond to the setting target)
This command returns the output status information (enabled/inhibited) that have been set by
communication in all slots.
This command returns the output status information (enabled/inhibited) that have been
set by communication.
Status
Status
Status
Examples of return value
If the instruction is executed on an output module other than the corresponding output modules, an
error is returned. (Error code 6 : Command that do not correspond to the setting target)
1
1
1
b
0bit : Returns 1, if all outp uts except blank
are 1.
Return value (binary)
1
1
1
1
6bit : Returns the satus of slot6
1bit : Returns the satus of slot1
2bit : Returns the satus of slot2
3bit : Returns the satus of slot3
4bit : Returns the satus of slot4
5bit : Returns the satus of slot5
17