SET_TON_DELAY_VIN [0Eh] [
Argument
]
800
-
60000
Argument:900 => 900 msec
Argument value
6.5.8
READ_TON_DELAY_VIN_PRM [1Eh] [09h] [1Dh] [00h]
This command returns the value (argument value) set by "SET_TON_DELAY_VIN" command.
Slot1
a
b
Slot2
c
SET_TON
_DELAY_VIN
SET_TON
_DELAY_SLOT
This command sets the delay time, in ms, from power-on to when power conversion starts. (See
Figure 6.5.3.)
The factory default is the value of the specification for the start-up time.
Store the setting value by "SYS_STORE_USER_SETTING" command after this command is
transmitted. Then, wait for 30 seconds or more after power-off. The setting will get enabled from
next start-up.
Figure 6.5.3 Timing diagram of "SET_TON_DELAY_VIN"
Settable range
Example of argument
Return value
When the delay time is set by the SET_TON_DELAY_SLOT command, its operation starts after the
one by "SET_TON_DELAY_VIN" command. (See Fig. 6.5.4.)
Figure 6.5.4 Timing diagram for "SET_TON_DELAY_SLOT" and "SET_TON_DELAY_VIN"
SET_TON_DELAY_VIN
Vin
Vout
output ON
output OFF
GI
(Com. remote on/off)
a
Vin
output ON
output OFF
Slot1 Vout
b
c
Slot2 Vout
GI
(Com. remote on/off)