SET_VOUT_FACTORY_SETTING [1Eh] [09h] [0Bh] [1Fh]
This command does not reset the adjustment by the internal potentiometer.
6.3.4
READ_VOUT_REFERENCE [1Eh] [09h] [1Bh] [00h]
6.3.5
SET_VOUT_UPPER_LIMIT [17h] [04h] [
Argument
]
Argument:241
⇒
24.1V
Argument value
Example of return value
Return value:5010 => 5.010V
This command sets a upper limit for the output voltage adjustment range.
The upper limit voltage, in V, of the output voltage adjustment range is set to the value of
"Argument/10".
This setting is applied to all operations related to the voltage adjustment (Internal potentiometer,
VTRM terminal, "SET_VOUT" command).
The voltage exceeding this upper limit is not outputted even in the constant current operation.
When the specified value is lower than the output voltage, the output voltage changes to the specified
value.
It cannot be set to the value which is the lower limit which has been set by
"SET_VOUT_LOWER_LIMIT" or less.
It cannot be set to the value which exceeds 120% of the rated voltage.
Example of argument
Return value
Return value
0
Table 6.3.2
"SET_VOUT_FACTORY_SETTING" Operation example
(
AM06-xxxB
)
Operation
Slot1 Output
Remark
* If the state has changed by volume adjustment, etc., the return value will be different from the
value set by "SET_VOUT".
The value of the output voltage that has been stored in the non-volatile memory by
"SYS_STORE_USER_SETTING" command does not change.
This command returns the controlling value for the output voltage.
6
Send "
SET_VOUT_FACTORY_SETTING"
0
12.5V
+0.3V & +0.2V => +0.5V
Table 6.3.3
"READ_VOUT_REFERENCE" Operation example
(
AM06-xxxC
)
Operation
Return value
Slot1 Output
Remark
1
5
Adjust output voltage to 10.2V by volume
ー
10.2V
+0.2V by volume
4
Send "
SET_VOUT"
&
"
10000"
10000
10.0V
3
Send "
SET_SELECTION_CH"
&
"1
"
1
12.3V
Select slot 1
2
Adjust output voltage to 12.3V by volume
ー
12.3V
+0.3V by volume
1
Power on
ー
12.0V
This command restores the output voltage set by "SET_VOUT" command to the factory
default value.
Return value
Send "
SET_VOUT"
&
"
10000"
24000
24.0V
2
Send "
READ_VOUT_PRM
"
24000
24.0V
3
Send "
READ_VOUT_REFERENCE
"
24000
24.0V
6
Send "
READ_VOUT_REFERENCE
"
22500
22.5V
4
Adjust output voltage to 22.5V by volume
ー
22.5V
-1.5V by volume
5
Send "
READ_VOUT_PRM
"
24000
22.5V
21
ver1.1E 2020.2.12